Korean J Anesthesiol.  2021 Apr;74(2):158-164. 10.4097/kja.20511.

Intraoperative aerosol box use: does an educational visual aid reduce contamination?

Affiliations
  • 1Department of Anesthesiology, Perioperative & Pain Medicine, Icahn School of Medicine at Mount Sinai, New York, NY, USA
  • 2Department of Anesthesia and Perioperative Care, University of California San Francisco, San Francisco, CA, USA
  • 3Department of Anesthesiology and Critical Care Medicine, Memorial Sloan Kettering Cancer Center, New York, NY, USA

Abstract

Background
The aerosol box was rapidly developed and disseminated to minimize viral exposure during aerosolizing procedures during the COVID-19 pandemic, yet users may not understand how to use and clean the device. This could potentially lead to increased viral exposure to subsequent patients and practitioners. We evaluated intraoperative contamination and aerosol box decontamination and the impact of a preoperative educational visual aid.
Methods
Using a double-blinded randomized design, forty-four anesthesiology trainees and faculty completed a simulated anesthetic case using an aerosol box contaminated with a fluorescent marker; half of the subjects received a visual aid prior to the simulation. Intraoperative contamination was evaluated at 10 standardized locations using an ultraviolet (UV) light. Next, subjects were instructed to clean the aerosol box for use on the next patient. Following cleaning, the box was evaluated for decontamination using an UV light.
Results
Median total contamination score was significantly reduced in the experimental group (5.0 vs. 10.0, P < 0.001). The aerosol box was completely cleaned by 36.4% of subjects in the experimental group compared to 4.5% in the control group (P = 0.009).
Conclusions
The use of a visual aid significantly decreased intraoperative contamination and improved box cleaning. Despite these findings, a potentially clinically significant amount of viral exposure may exist. Thorough evaluation of the risks and benefits of the aerosol box should be completed prior to use. If an aerosol box is used, a visual aid should be considered to remind practitioners how to best use and clean the box.

Keyword

Infection control; Airway management; Equipment and supplies; Audiovisual aids; High fidelity simulation training; Anesthesiology
Full Text Links
  • KJAE
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr