J Korean Acad Pediatr Dent.  2020 May;47(2):176-187. 10.5933/JKAPD.2020.47.2.176.

Validity, Reliability and Reproducibility of Space Analysis using Digital Model taken via Model Scanner and Intraoral Scanner: An In vivo Study

Affiliations
  • 1Department of Pediatric Dentistry, Dental Clinic Center, Hallym University Sacred Heart Hospital
  • 2Department of Pediatric Dentistry, College of Dentistry, Dankook University

Abstract

The purpose of this study is to evaluate validity, reliability and reproducibility of tooth width (TW), arch length (AL) and arch length discrepancy (ALD) measured on a digital model taken via 3-dimensional model scanner and intraoral scanner compared to a plaster model.
A total of 30 patients aged 12 to 18 were eligible for the study. 3 types of models were acquired from each patient: a conventional plaster model (P), a model scanned digital model (MSD) taken via Freedom UHD® and an intraoral scanned digital model (ISD) taken via CS3600® in-vivo. The reliability of TW and AL in each group was evaluated using Pearson’s correlation coefficient, while the reproducibility was evaluated with intraclass correlation coefficient. The validity of space analysis was assessed by paired t-test.
As a result, all measurements of P, MSD and ISD groups showed favorable reliability and reproducibility. Most of measurements for space analysis in MSD group and TW in ISD group also presented high validity. AL and ALD presented statistically significant difference between P and ISD group. The validity of measurements of space analysis in ISD group was short in doubt to valid, but clinically acceptable. Both MSD and ISD are clinically acceptable to use for space analysis but clinician should be aware that errors can be found using a digital model.