Use of Three-dimensional Transesophageal Echocardiography for the Chiari Network

Affiliations
  • 1Department of Anesthesia and Pain Medicine, Pusan National University School of Medicine, Busan, Korea

Abstract

The Chiari network is an embryonic remnant of the sinus venosus valve, which is characterized by a fenestrated, netlike structure in the right atrium and has the potential to be misdiagnosed as another right atrial pathology. Additionally, the Chiari network has been frequently reported to entrap intracardiac devices during surgical procedures. In this case report, we present two patients with a Chiari network confirmed by three-dimensional transesophageal echocardiography, which assisted in preventing device entrapment during intracardiac procedures.

Keyword

Chiari network; Swan-Ganz Catheterization; Three-dimensional echocardiography

Figure

  • Fig. 1 (A) Two-dimensional transesophageal echocardiography (TEE) showing a linear structure in the right atrium (arrow). (B) Three-dimensional TEE clearly showing a net-like structure connected to the edge of the IVC and interatrial septum. IAS: interatrial septum; IVC: inferior vena cava; LA: left atrium; RA: right atrium; TV: tricuspid valve.

  • Fig. 2 (A) Two-dimensional transesophageal echocardiography (TEE) imaging does not clearly show the location of the Chiari network (arrow) in relation to the pulmonary artery catheter (PAC, *) (B) Three-dimensional TEE imaging shows that the PAC(*) successfully passed through the tricuspid valve without being entrapped in the Chiari network (arrow). IAS: interatrial septum; IVC: inferior vena cava; LA: left atrium; RA: right atrium; TV: tricuspid valve.


Reference

1. Loukas M, Sullivan A, Tubbs RS, Weinhaus AJ, Derderian T, Hanna M. Chiari’s network: review of the literature. Surg Radiol Anat. 2010; 32:895–901.
Article
2. Werner JA, Cheitlin MD, Gross BW, Speck SM, Ivey TD. Echocardiographic appearance of the Chiari network: differentiation from right-heart pathology. Circulation. 1981; 63:1104–9.
Article
3. Pothineni KR, Nanda NC, Burri MV, Singh A, Panwar SR, Gandhari S. Live/real time three-dimensional transthoracic echocardiographic visualization of Chiari network. Echocardiography. 2007; 24:995–7.
Article
4. Sakamoto A, Urushida T, Sakakibara T, Sano M, Suwa K, Saitoh T, et al. Accidental Entrapment of Electrical Mapping Catheter by Chiari’s Network in Right Atrium during Catheter Ablation Procedure. Case Rep Cardiol. 2016; 2016:1302473.
Article
5. Hightower JS, Taylor AG, Ursell PC, LaBerge JM. The Chiari Network: a rare cause of intracardiac guide wire entrapment. J Vasc Interv Radiol. 2015; 26:604–6.
Article
6. Dissmann R, Schröder J, Völler H, Behrens S. Entrapment of pacemaker lead by a large net like Eustachian valve within the right atrium. Clin Res Cardiol. 2006; 95:241–3.
7. Powell ED, Mullaney JM. The Chiari network and the valve of the inferior vena cava. Br Heart J. 1960; 22:579–84.
Article
8. Yoshimura M, Toriumi T. Guidewire Entrapment in the Chiari Network. J Cardiothorac Vasc Anesth. 2016; 30:e24–25.
Article
9. Hahn RT, Abraham T, Adams MS, Bruce CJ, Glas KE, Lang RM, et al. Guidelines for performing a comprehensive transesophageal echocardiographic examination: recommendations from the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists. Anesth Analg. 2014; 118:21–68.
Article
10. Croinin B, Robbins R, Maus T. Pulmonary artery catheter placement using transesophageal echocardiography. J Cardiothorac Vasc Anesth. 2017; 31:178–83.
11. Faletra FF, Pedrazzini G, Pasotti E, Muzzarelli S, Dequarti MC, Murzilli R, et al. 3D TEE during catheter-based interventions. JACC Cardiovasc Imaging. 2014; 7:292–308.
Article
Full Text Links
  • KMJ
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr