Clin Exp Otorhinolaryngol.  2020 Nov;13(4):422-428. 10.21053/ceo.2019.01529.

Efficacy of Transcartilaginous Electrodes for Intraoperative Neural Monitoring During Thyroid Surgery

Affiliations
  • 1Department of Otolaryngology-Head and Neck Surgery, Hanyang University College of Medicine, Seoul, Korea

Abstract


Objectives
. This study was conducted evaluate the efficacy of electromyography (EMG) using transcartilaginous (TC) electrodes through the thyroid cartilage and perichondrium.
Methods
. We prospectively collected EMG data from intraoperative neuromonitoring (IONM) of 54 nerves at risk in 38 patients during thyroidectomy. We followed standardized IONM procedures in all operations. EMG signals from both endotracheal tube (ET) electrodes and TC needle electrodes were recorded simultaneously. We compared the characteristics of the EMG signals and the efficacy of both methods.
Results
. Significantly higher mean EMG amplitudes were recorded by TC electrodes than by ET electrodes in all four-step procedures (V1-R1-R2-V2, P<0.001). Loss of signal (LOS) occurred in five patients in ET electrodes, but in only two patients in TC electrodes. Postoperative laryngoscopy revealed recurrent laryngeal nerve palsy in the two patients who showed LOS from both the ET and TC electrodes, and vocal cord movement was intact in the other three patients. Therefore, the positive predictive values of LOS in ET and TC electrodes were 40% and 100%, respectively.
Conclusion
. EMG recording using TC needle electrodes is feasible and effective, making it a good alternative technique for IONM.

Keyword

Intraoperative Neurophysiological Monitoring; Thyroidectomy; Recurrent Laryngeal Nerve; Electrode

Figure

  • Fig. 1. Electrode placement. (A) Needle electrodes inserted through the thyroid cartilage. (B) A 22-mm twisted pair of needle electrodes (Medtronic Xomed, Jacksonville, FL, USA).

  • Fig. 2. Electromyography (EMG) signals from both the endotracheal tube and thyroid cartilage electrodes during each part of the standardized procedure (V1, R1, R2, V2). A, B: EMG signals from the right and left endotracheal tube electrodes, C: EMG signal from the thyroid cartilage electrodes.


Cited by  3 articles

Application of Skin Electrodes for Intraoperative Neuromonitoring of Recurrent Laryngeal Nerve
Hyoung Shin Lee
Korean J Otorhinolaryngol-Head Neck Surg. 2021;64(1):1-6.    doi: 10.3342/kjorl-hns.2020.00815.

A New Era of Intraoperative Neuromonitoring: Beyond the Electromyography Endotracheal Tube During Thyroid Surgery
Sung-Chan Shin, Byung-Joo Lee
Clin Exp Otorhinolaryngol. 2020;13(4):324-325.    doi: 10.21053/ceo.2020.01158.

Intraoperative Neuromonitoring System Using Needle and Skin Electrode during Thyroid Surgery
Sung-Chan Shin, Myeonggu Seo, Yong-Il Cheon, Byung-Joo Lee
Int J Thyroidol. 2022;15(1):17-22.    doi: 10.11106/ijt.2022.15.1.17.


Reference

1. Vasileiadis I, Karatzas T, Charitoudis G, Karakostas E, Tseleni-Balafouta S, Kouraklis G. Association of intraoperative neuromonitoring with reduced recurrent laryngeal nerve injury in patients undergoing total thyroidectomy. JAMA Otolaryngol Head Neck Surg. 2016; Oct. 142(10):994–1001.
Article
2. Riddell VH. Injury to recurrent laryngeal nerves during thyroidectomy; a comparison between the results of identification and non-identification in 1022 nerves exposed to risk. Lancet. 1956; Sep. 271(6944):638–41.
3. Jatzko GR, Lisborg PH, Muller MG, Wette VM. Recurrent nerve palsy after thyroid operations--principal nerve identification and a literature review. Surgery. 1994; Feb. 115(2):139–44.
4. Witt RL. Recurrent laryngeal nerve electrophysiologic monitoring in thyroid surgery: the standard of care? J Voice. 2005; Sep. 19(3):497–500.
Article
5. Chan WF, Lang BH, Lo CY. The role of intraoperative neuromonitoring of recurrent laryngeal nerve during thyroidectomy: a comparative study on 1000 nerves at risk. Surgery. 2006; Dec. 140(6):866–72.
Article
6. Barczynski M, Konturek A, Cichon S. Randomized clinical trial of visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomy. Br J Surg. 2009; Mar. 96(3):240–6.
7. Flisberg K, Lindholm T. Electrical stimulation of the human recurrent laryngeal nerve during thyroid operation. Acta Otolaryngol Suppl. 1969; 263:63–7.
Article
8. Gardner IH, Doherty GM, McAneny D. Intraoperative nerve monitoring during thyroid surgery. Curr Opin Endocrinol Diabetes Obes. 2016; Oct. 23(5):394–9.
Article
9. Rea JL. Postcricoid surface laryngeal electrode. Ear Nose Throat J. 1992; Jun. 71(6):267–9.
Article
10. Tschopp K, Probst R. New aspects in surgery of the thyroid gland with intraoperative monitoring of the recurrent laryngeal nerve. Laryngorhinootologie. 1994; Nov. 73(11):568–72.
11. Mermelstein M, Nonweiler R, Rubinstein EH. Intraoperative identification of laryngeal nerves with laryngeal electromyography. Laryngoscope. 1996; Jun. 106(6):752–6.
Article
12. Khan A, Pearlman RC, Bianchi DA, Hauck KW. Experience with two types of electromyography monitoring electrodes during thyroid surgery. Am J Otolaryngol. 1997; Mar-Apr. 18(2):99–102.
Article
13. Maloney RW, Murcek BW, Steehler KW, Sibly D, Maloney RE. A new method for intraoperative recurrent laryngeal nerve monitoring. Ear Nose Throat J. 1994; Jan. 73(1):30–3.
Article
14. Kwak HY, Kim HY. The present and future of intraoperative neuromonitoring in thyroid surgery. Korean J Endocr Surg. 2014; Jun. 14(2):67–75.
Article
15. Randolph GW, Dralle H; International Intraoperative Monitoring Study Group, Abdullah H, Barczynski M, Bellantone R, et al. Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement. Laryngoscope. 2011; Jan. 121 Suppl 1:S1–16.
Article
16. Tsai CJ, Tseng KY, Wang FY, Lu IC, Wang HM, Wu CW, et al. Electromyographic endotracheal tube placement during thyroid surgery in neuromonitoring of recurrent laryngeal nerve. Kaohsiung J Med Sci. 2011; Mar. 27(3):96–101.
Article
17. Zhao Y, Li C, Zhang D, Zhou L, Liu X, Li S, et al. Experimental study of needle recording electrodes placed on the thyroid cartilage for neuromonitoring during thyroid surgery. Br J Surg. 2019; Feb. 106(3):245–54.
Article
18. Lu IC, Chu KS, Tsai CJ, Wu CW, Kuo WR, Chen HY, et al. Optimal depth of NIM EMG endotracheal tube for intraoperative neuromonitoring of the recurrent laryngeal nerve during thyroidectomy. World J Surg. 2008; Sep. 32(9):1935–9.
Article
19. Kim HY, Tufano RP, Randolph G, Barczynski M, Wu CW, Chiang FY, et al. Impact of positional changes in neural monitoring endotracheal tube on amplitude and latency of electromyographic response in monitored thyroid surgery: results from the porcine experiment. Head Neck. 2016; Apr. 38 Suppl 1:E1004–8.
Article
20. Chiang FY, Lu IC, Chang PY, Dionigi G, Randolph GW, Sun H, et al. Comparison of EMG signals recorded by surface electrodes on endotracheal tube and thyroid cartilage during monitored thyroidectomy. Kaohsiung J Med Sci. 2017; Oct. 33(10):503–9.
Article
21. Chiang FY, Lu IC, Chen HC, Chen HY, Tsai CJ, Hsiao PJ, et al. Anatomical variations of recurrent laryngeal nerve during thyroid surgery: how to identify and handle the variations with intraoperative neuromonitoring. Kaohsiung J Med Sci. 2010; Nov. 26(11):575–83.
Article
22. Spahn JG, Bizal J, Ferguson S, Lingeman RE. Identification of the motor laryngeal nerves: a new electrical stimulation technique. Laryngoscope. 1981; Nov. 91(11):1865–8.
23. Brauckhoff M, Walls G, Brauckhoff K, Thanh PN, Thomusch O, Dralle H. Identification of the non-recurrent inferior laryngeal nerve using intraoperative neurostimulation. Langenbecks Arch Surg. 2002; Jan. 386(7):482–7.
Article
24. Dralle H, Sekulla C, Lorenz K, Brauckhoff M, Machens A; German IONM Study Group. Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery. World J Surg. 2008; Jul. 32(7):1358–66.
Article
25. Bergenfelz A, Salem AF, Jacobsson H, Nordenstrom E, Almquist M; Steering Committee for the Scandinavian Quality Register for Thyroid, Parathyroid and Adrenal Surgery (SQRTPA). Risk of recurrent laryngeal nerve palsy in patients undergoing thyroidectomy with and without intraoperative nerve monitoring. Br J Surg. 2016; Dec. 103(13):1828–38.
Article
26. Pisanu A, Porceddu G, Podda M, Cois A, Uccheddu A. Systematic review with meta-analysis of studies comparing intraoperative neuromonitoring of recurrent laryngeal nerves versus visualization alone during thyroidectomy. J Surg Res. 2014; May. 188(1):152–61.
Article
27. Shedd DP, Burget GC. Identification of the recurrent laryngeal nerve. Arch Surg. 1966; Jun. 92(6):861–4.
Article
28. Chiang FY, Lu IC, Chen HC, Chen HY, Tsai CJ, Lee KW, et al. Intraoperative neuromonitoring for early localization and identification of recurrent laryngeal nerve during thyroid surgery. Kaohsiung J Med Sci. 2010; Dec. 26(12):633–9.
Article
29. Eltzschig HK, Posner M, Moore FD Jr. The use of readily available equipment in a simple method for intraoperative monitoring of recurrent laryngeal nerve function during thyroid surgery: initial experience with more than 300 cases. Arch Surg. 2002; Apr. 137(4):452–6.
Article
30. Alesina PF, Rolfs T, Hommeltenberg S, Hinrichs J, Meier B, Mohmand W, et al. Intraoperative neuromonitoring does not reduce the incidence of recurrent laryngeal nerve palsy in thyroid reoperations: results of a retrospective comparative analysis. World J Surg. 2012; Jun. 36(6):1348–53.
Article
31. Calo PG, Medas F, Gordini L, Podda F, Erdas E, Pisano G, et al. Interpretation of intraoperative recurrent laryngeal nerve monitoring signals: the importance of a correct standardization. Int J Surg. 2016; Apr. 28 Suppl 1:S54–8.
32. Rulli F, Ambrogi V, Dionigi G, Amirhassankhani S, Mineo TC, Ottaviani F, et al. Meta-analysis of recurrent laryngeal nerve injury in thyroid surgery with or without intraoperative nerve monitoring. Acta Otorhinolaryngol Ital. 2014; Aug. 34(4):223–9.
33. Yang S, Zhou L, Lu Z, Ma B, Ji Q, Wang Y. Systematic review with meta-analysis of intraoperative neuromonitoring during thyroidectomy. Int J Surg. 2017; Mar. 39:104–13.
Article
34. Snyder SK, Hendricks JC. Intraoperative neurophysiology testing of the recurrent laryngeal nerve: plaudits and pitfalls. Surgery. 2005; Dec. 138(6):1183–91.
Article
35. Wu CW, Chiang FY, Randolph GW, Dionigi G, Kim HY, Lin YC, et al. Transcutaneous recording during intraoperative neuromonitoring in thyroid surgery. Thyroid. 2018; Nov. 28(11):1500–7.
Article
36. Chavez KV, Ramirez J, Pantoja JP, Sierra M, Velazquez-Fernandez D, Herrera MF. Continuous intraoperative neural monitoring in thyroid surgery: a Mexican experience. Updates Surg. 2017; Dec. 69(4):505–8.
Article
37. Sarkis LM, Zaidi N, Norlen O, Delbridge LW, Sywak MS, Sidhu SB. Bilateral recurrent laryngeal nerve injury in a specialized thyroid surgery unit: would routine intraoperative neuromonitoring alter outcomes? ANZ J Surg. 2017; May. 87(5):364–7.
Article
38. Sitges-Serra A, Gallego-Otaegui L, Fontane J, Trillo L, Lorente-Poch L, Sancho J. Contralateral surgery in patients scheduled for total thyroidectomy with initial loss or absence of signal during neural monitoring. Br J Surg. 2019; Mar. 106(4):404–11.
Article
39. Sadowski SM, Soardo P, Leuchter I, Robert JH, Triponez F. Systematic use of recurrent laryngeal nerve neuromonitoring changes the operative strategy in planned bilateral thyroidectomy. Thyroid. 2013; Mar. 23(3):329–33.
Article
40. Schneider R, Randolph GW, Dionigi G, Wu CW, Barczynski M, Chiang FY, et al. International neural monitoring study group guideline 2018 part I: staging bilateral thyroid surgery with monitoring loss of signal. Laryngoscope. 2018; Oct. 128 Suppl 3:S1–17.
Article
41. Genther DJ, Kandil EH, Noureldine SI, Tufano RP. Correlation of final evoked potential amplitudes on intraoperative electromyography of the recurrent laryngeal nerve with immediate postoperative vocal fold function after thyroid and parathyroid surgery. JAMA Otolaryngol Head Neck Surg. 2014; Feb. 140(2):124–8.
Article
42. Barczynski M, Randolph GW, Cernea C; International Neural Monitoring Study Group in Thyroid and Parathyroid Surgery. International survey on the identification and neural monitoring of the EBSLN during thyroidectomy. Laryngoscope. 2016; Jan. 126(1):285–91.
43. Caragacianu D, Kamani D, Randolph GW. Intraoperative monitoring: normative range associated with normal postoperative glottic function. Laryngoscope. 2013; Dec. 123(12):3026–31.
Article
44. Pavier Y, Saroul N, Pereira B, Tauveron I, Gilain L, Mom T. Acute prediction of laryngeal outcome during thyroid surgery by electromyographic laryngeal monitoring. Head Neck. 2015; Jun. 37(6):835–9.
Article
Full Text Links
  • CEO
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles