Korean J Thorac Cardiovasc Surg.  2020 Apr;53(2):64-72. 10.5090/kjtcs.2020.53.2.64.

Outcomes and Patency of Complex Configurations of Composite Grafts Using Bilateral Internal Thoracic Arteries

Affiliations
  • 1Department of Thoracic and Cardiovascular Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea
  • 2Department of Thoracic and Cardiovascular Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea

Abstract

Background
It is generally agreed that using a bilateral internal thoracic artery (BITA) composite graft improves long-term survival after coronary artery bypass grafting (CABG). Although the left internal thoracic artery (LITA)-based Y-composite graft is widely adopted, technical or anatomical difficulties necessitate complex configurations. We aimed to investigate whether BITA configuration impacts survival or patency in patients undergoing coronary revascularization.
Methods
Between January 2006 and June 2017, 1,161 patients underwent CABG at Seoul National University Bundang Hospital, where the standard technique is a LITA-based Y-composite graft with the right internal thoracic artery (RITA) sequentially anastomosed to non-left anterior descending (LAD) targets. Total of 160 patients underwent CABG using BITA with modifications. Their medical records and imaging data were reviewed retrospectively to investigate technical details, clinical outcomes, and graft patency.
Results
Modifications of the typical Y-graft (group 1, n=90), LITA-based I-graft (group 2, n=39), and RITA-based composite graft (group 3, n=31) were used due to insufficient RITA length (47%), problems using LITA (28%), and target vessel anatomy (25%). The overall 30- day mortality rate was 1.9%. Among 116 patients who underwent computed tomography or conventional angiography at a mean interval of 29.9±33.1 months postoperatively, the graft patency rates were 98.7%, 95.3%, and 83.6% for the LAD, left circumflex artery, and right coronary artery territories, respectively. Patency rates for the inflow, secondary, and tertiary grafts were 98.2%, 90.5%, and 80.4%, respectively. The RITA-based graft (group 3) had the lowest patency rate of the various configurations (p<0.011).
Conclusion
LITA-based Y composite graft, showed satisfactory clinical outcomes and patency whereas modifications of RITA- based composite graft had the lowest patency and 5-year survival rates. Therefore, when using RITA-based composite graft, other options should be considered before proceeding atypical configurations.

Keyword

Coronary artery bypass; Composite graft; Bilateral internal thoracic artery; Coronary artery disease
Full Text Links
  • KJTCS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr