Clin Orthop Surg.  2020 Jun;12(2):158-165. 10.4055/cios19069.

Anthropometry of Nonarthritic Asian Knees: Is It Time for a Race-Specific Knee Implant?

Affiliations
  • 1Department of Orthopaedics, Sir HN Reliance Foundation Hospital and Research Center, Mumbai, India
  • 2Department of Applied Mathematics, Harvard University, Cambridge, MA, USA

Abstract

Background
This study was done to study the anthropometry of nonarthritic Asian knees; to determine the differences in morphology between knees of different ethnicities and to compare the knee anthropometry values with sizes of available knee implants.
Methods
Magnetic resonance imaging scans of 100 nonarthritic Indian knees were analyzed. Anteroposterior (AP) length, mediolateral (ML) length, and aspect ratio of the distal femur and proximal tibia, patellar length, and patellar tendon length were measured. These values were compared with values of other ethnicities from literature. The values were also compared with sizes of available knee implants and evaluated for mismatch.
Results
All the parameters of female knees were significantly smaller than those of male knees (p < 0.05). The distal femur of Indian knees resembled that of Chinese knees with similar AP and ML lengths and aspect ratio. The distal femur of Indian knees had a significantly smaller AP, ML, and aspect ratio than those of Hispanic knees did. In comparison to Caucasian distal femur, Indian knees had smaller AP and ML lengths and larger aspect ratio. In terms of the proximal tibia, the Indian knees were smaller than Chinese (only ML), Caucasian (AP and ML) and Hispanic (AP and ML) knees. On comparison with implant sizes, there was a mismatch between the distal femur morphology and the dimensions of all implants. For a given AP length, the ML dimensions of all implants were smaller than the measured ML length of the knee. However, the tibial components of all the studied implants correlated well with the tibial morphology.
Conclusions
Distinct anthropometric differences exist between knees of different ethnicities. The knees of females were smaller than the knees of males. In Indian knees, the ML-AP aspect ratio of the distal femur was higher than that of the currently available femoral components. These results suggest the need for race-specific knee implants.

Keyword

Knee joint; Arthroplasty; Knee implants
Full Text Links
  • CIOS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr