J Korean Ophthalmol Soc.  2020 May;61(5):532-537. 10.3341/jkos.2020.61.5.532.

Comparison of Pericardial Patch Graft Thickness for Glaucoma Implant, Using Anterior Segment Optical Coherence Tomography

Affiliations
  • 1Myung-Gok Eye Research Institute, Kim’s Eye Hospital, Konyang University College of Medicine, Seoul, Korea

Abstract

Purpose
To compare the thickness of the processed pericardial patch graft for glaucoma implant tube coverage using anterior segment optical coherence tomography (AS-OCT).
Methods
Thicknesses of seven samples of two pericardial patch grafts (Tutoplast pericardium, IOP Inc, Costa Mesa, CA, USA; pericardium LYO, DCI Donor Services, Inc., Nashville, TN, USA) were measured using AS-OCT (CASIA2, Tomey Corporation, Nagoya, Japan). The thickness of each sample was measured at the center and eight points with 45-degree angular distance, 2 mm from the center. The thickness was measured using AS-OCT program tools.
Results
The median thicknesses were 219 μm for Tutoplast pericardium and 157 μm for pericardium LYO. Tutoplast pericardium was significantly thicker than pericardium LYO (p = 0.001); pericardium LYO had a wider interquartile range within each sample, compared to Tutoplast pericardium (p = 0.017).
Conclusions
The thickness of the Tutoplast pericardium was greater and less variable than that of the pericardium LYO. These findings should be considered when choosing processed pericardium for coverage of glaucoma implants.

Keyword

Anterior segment optical coherence tomography; Glaucoma implant; Tube erosion; Pericardium patch graft