J Korean Ophthalmol Soc.  2019 Jan;60(1):9-15. 10.3341/jkos.2019.60.1.9.

The Effect of Preoperative Corneal Asphericity on the Refractive Outcomes of Multifocal Intraocular Lens Implantation

Affiliations
  • 1Department of Ophthalmology and Visual Science, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea. sara514@catholic.ac.kr

Abstract

PURPOSE
To analyze the effects of preoperative corneal asphericity on the refractive outcomes of multifocal intraocular lens implantation by correlating Q-values on anterior corneal surfaces and the prediction errors after surgery.
METHODS
Fifty-six eyes of 39 patients who underwent phacoemulsification, and multifocal intraocular lens implantation were included in this retrospective study. Intraocular lens power was calculated using the SRK/T, Hoffer Q, and Haigis formulas. The Q-values were measured at 6 mm, 7 mm, 8 mm, 9 mm, and 10 mm with a rotating Sheimpflug camera (Pentacam®, Oculus, Wetzlar, Germany). The relationship between the prediction errors and the Q-values at 6 mm, 7 mm, 8 mm, 9 mm, and 10 mm were assessed by linear regression.
RESULTS
Two different multifocal intraocular lens models (Acrysof IQ RESTOR +2.5D SV25T0 [Alcon Laboratories Inc., Fort Worth, TX, USA] and ZEISS AT LISA tri 839MP [Carl Zeiss Meditec AG, Inc., Jena, Germany]) were implanted in 56 eyes. In both groups, regression analyses showed statistically significant relationships between the prediction errors and the Q-values at 6 mm, 7 mm, and 8 mm using the SRK/T formula. The correlation coefficient between the Q-values and the prediction errors were higher using the SRK/T formula than using the Hoffer-Q and Haigis formulas.
CONCLUSIONS
Corneal asphericity affected refractive power during implantation of a multifocal intraocular lens and, as the preoperative Q-value increased, it resulted in a hyperopic refractive outcome for oblate corneas. These results were especially prominent when the SRK/T formula was used.

Keyword

Cataract; Cornea; Intraocular lenses; Refractive errors

MeSH Terms

Cataract
Cornea
Humans
Lens Implantation, Intraocular*
Lenses, Intraocular*
Linear Models
Phacoemulsification
Refractive Errors
Retrospective Studies

Figure

  • Figure 1 Scatter spot of axial length and the PE of the SRK/T formula. PE = prediction error; D = diopter.

  • Figure 2 Regression line showing the relationship between the PE of the SRK/T formula and corneal asphericity (Q-value 6 mm, 7 mm, 8 mm) in the (A) Acrysof group (left) and (B) ZEISS group (right). Straight line represent regression line, and two curved lines represent the 95% prediction interval. Scatter spot means patient distribution. PE = prediction error.


Reference

1. Haigis W, Lege B, Miller N, Schneider B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol. 2000; 238:765–773.
Article
2. Hoffer KJ. The Hoffer Q formula: a comparison of theoretic and regression formulas. J Cataract Refract Surg. 1993; 19:700–712.
Article
3. Holladay JT, Prager TC, Chandler TY, et al. A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg. 1988; 14:17–24.
Article
4. Retzlaff JA, Sanders DR, Kraff MC. Development of the SRK/T intraocular lens implant power calculation formula. J Cataract Refract Surg. 1990; 16:333–340.
Article
5. Savini G, Hoffer KJ, Barboni P. Influence of corneal asphericity on the refractive outcome of intraocular lens implantation in cataract surgery. J Cataract Refract Surg. 2015; 41:785–789.
Article
6. Kang SI, Moon K, Jun JH. Accuracy of three intraocular lens-power formulas in predicting refractive outcomes in different intraocular lenses. J Korean Ophthalmol Soc. 2016; 57:1891–1896.
Article
7. Norrby S. Sources of error in intraocular lens power calculation. J Cataract Refract Surg. 2008; 34:368–376.
Article
8. Xiong Y, Li J, Wang N, et al. The analysis of corneal asphericity (Q value) and its related factors of 1,683 Chinese eyes older than 30 years. PLoS One. 2017; 12:e0176913.
Article
9. Fuller DG, Alperin D. Variations in corneal asphericity (Q value) between African-Americans and whites. Optom Vis Sci. 2013; 90:667–673.
Article
10. Savini G, Hoffer KJ, Barboni P, et al. Corneal asphericity and IOL power calculation in eyes with aspherical IOLs. J Refract Surg. 2017; 33:476–481.
Article
11. Holladay JT. Effect of corneal asphericity and spherical aberration on intraocular lens power calculations. J Cataract Refract Surg. 2015; 41:1553–1554.
Article
12. Shammas HJ, Chan S. Precision of biometry, keratometry, and refractive measurements with a partial coherence interferometry-keratometry device. J Cataract Refract Surg. 2010; 36:1474–1478.
Article
13. Eom Y, Kang SY, Song JS, Kim HM. Use of corneal power-specific constants to improve the accuracy of the SRK/T formula. Ophthalmology. 2013; 120:477–481.
Article
14. Olsen T, Corydon L, Gimbel H. Intraocular lens power calculation with an improved anterior chamber depth prediction algorithm. J Cataract Refract Surg. 1995; 21:313–319.
Article
15. Olsen T, Hoffmann P. C constant: new concept for ray tracing-assisted intraocular lens power calculation. J Cataract Refract Surg. 2014; 40:764–773.
Article
16. Melles RB, Holladay JT, Chang WJ. Accuracy of intraocular lens calculation formulas. Ophthalmology. 2018; 125:169–178.
Article
Full Text Links
  • JKOS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr