Int J Thyroidol.  2018 May;11(1):31-40. 10.11106/ijt.2018.11.1.31.

Diagnostic Performance of Shear Wave Elastography as Add-on Test in Thyroid Nodules: a Systematic Review and Meta-Analysis

Affiliations
  • 1Division of New Health Technology Assessment, National Evidence-based Healthcare Collaborating Agency, Seoul, Korea. lionmain@catholic.ac.kr
  • 2Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea. shkim@neca.re.kr

Abstract

BACKGROUND AND OBJECTIVES
The diagnostic performance of shear wave elastography (SWE) combined with ultrasound (US) in the differential diagnosis of thyroid nodules was evaluated.
MATERIALS AND METHODS
459 articles were collected using KoreaMed, Ovid-MEDLINE, Ovid-EMBASE, and Cochrane Library. The searching words were "˜{(elastography and shear).mp. OR SWE.mp. OR acoustic radiation force impulse.mp. OR ARFI.mp. OR acuson.mp. OR aixplorer.mp.}'. Two authors independently performed article selection and evaluation of the quality of studies with Scottish Intercollegiate Guidelines Network tool.
RESULTS
2582 specimens (thyroid nodules) from 11 studies selected were included in this review. Combined use of US and SWE was reported higher specificity in five literatures, lower specificity in five studies, and no changes in 1 study when compared to US. We performed meta-analysis using data from 10 studies. The pooled sensitivity and specificity of US and SWE group for the differential diagnosis of benign and malignant nodules were 0.91 (I2=83.4%), 0.73 (I2=95.9%). The pooled sensitivity and specificity of US alone group were 0.88 (I2=93.2%), 0.71 (I2=92.7%).
CONCLUSION
SWE is not effective in the differential diagnosis of thyroid nodules to minimize unnecessary biopsy of nodules. The included studies showed significant heterogeneity of results.

Keyword

Thyroid nodule; Shear wave elastography; Diagnostic performance; Effectiveness

MeSH Terms

Acoustics
Biopsy
Diagnosis, Differential
Elasticity Imaging Techniques*
Population Characteristics
Sensitivity and Specificity
Thyroid Gland*
Thyroid Nodule*
Ultrasonography

Figure

  • Fig. 1. Literature search flow diagram. SWE: shear wave elastography, US: ultrasonography.

  • Fig. 2. Forest plot of sensitivities for SWE+ US and US. CI: confidential interval, NA: not available, SWE: shear wave elastography, US: ultrasonography, VTI: virtual touch tissue imaging, VTQ: virtual touch tissue quantification

  • Fig. 3. Forest plot of specificities for SWE+ US and US. CI: confidential interval, NA: not available, SWE: shear wave elastography, US: ultrasonography, VTI: virtual touch tissue imaging, VTQ: virtual touch tissue quantification


Reference

1). Yi GH. Updated guidelines for the management of thyroid nodule. Korean J Med. 2011; 80(2):158–61.
2). Park YJ, Hyun MK, Kang MJ, Shim JY, Lee JY, Kim KW, et al. Epidemiology of thyroid nodules in screening. Seoul, Korea: National Evidence Collaborating Agency;2015. p. 1–66.
3). Gharib H, Papini E. Thyroid nodules: clinical importance, assessment, and treatment. Endocrinol Metab Clin North Am. 2007; 36(3):707–35. vi.
Article
4). Ross DS. Nonpalpable thyroid nodules–managing an epidemic. J Clin Endocrinol Metab. 2002; 87(5):1938–40.
Article
5). Tan GH, Gharib H. Thyroid incidentalomas: management approaches to nonpalpable nodules discovered incidentally on thyroid imaging. Ann Intern Med. 1997; 126(3):226–31.
Article
6). Yi KH, Park YJ, Koong SS, Kim JH, Na DG, Ryu JS, et al. Revised Korean Thyroid Association Management Guidelines for patients with thyroid nodules and thyroid cancer. Endocrinol Metab. 2010; 25(4):270–97.
Article
7). Tian W, Hao S, Gao B, Jiang Y, Zhang S, Guo L, et al. Comparison of diagnostic accuracy of realtime elastography and shear wave elastography in differentiation malignant from benign thyroid nodules. Medicine (Baltimore). 2015; 94(52):e2312.
Article
8). Xing P, Wu L, Zhang C, Li S, Liu C, Wu C. Differentiation of benign from malignant thyroid lesions: calculation of the strain ratio on thyroid sonoelastography. J Ultrasound Med. 2011; 30(5):663–9.
9). Zhang B, Ma X, Wu N, Liu L, Liu X, Zhang J, et al. Shear wave elastography for differentiation of benign and malignant thyroid nodules: a metaanalysis. J Ultrasound Med. 2013; 32(12):2163–9.
10). Tamsel S, Demirpolat G, Erdogan M, Nart D, Karadeniz M, Uluer H, et al. Power Doppler US patterns of vascularity and spectral Doppler US parameters in predicting malignancy in thyroid nodules. Clin Radiol. 2007; 62(3):245–51.
Article
11). Cappelli C, Castellano M, Pirola I, Gandossi E, De Martino E, Cumetti D, et al. Thyroid nodule shape suggests malignancy. Eur J Endocrinol. 2006; 155(1):27–31.
Article
12). Ophir J, Alam SK, Garra B, Kallel F, Konofagou E, Krouskop T, et al. Elastography: ultrasonic estimation and imaging of the elastic properties of tissues. Proc Inst Mech Eng H. 1999; 213(3):203–33.
Article
13). Lerner RM, Huang SR, Parker KJ. "Sonoelasticity" images derived from ultrasound signals in mechanically vibrated tissues. Ultrasound Med Biol. 1990; 16(3):231–9.
Article
14). Dong FJ, Li M, Jiao Y, Xu JF, Xiong Y, Zhang L, et al. Acoustic radiation force impulse imaging for detecting thyroid nodules: a systematic review and pooled metaanalysis. Med Ultrason. 2015; 17(2):192–9.
Article
15). Zhan J, Diao XH, Chai QL, Chen Y. Comparative study of acoustic radiation force impulse imaging with realtime elastography in differential diagnosis of thyroid nodules. Ultrasound Med Biol. 2013; 39(12):2217–25.
Article
16). Scottish Intercollegiate Guidelines Network. SIGN methodology checklist. [cited February 4, 2018]. Available from. http://www.sign.ac.uk/checklists-and-notes.html.
17). Scottish Intercollegiate Guidelines Network. SIGN 50- a guideline developer's handbook. [cited February 4, 2018]. Available from. http://www.sign.ac.uk/assets/sign50_2015.pdf.
18). Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. BMJ. 2003; 327(7414):557–60.
Article
19). Duan SB, Yu J, Li X, Han ZY, Zhai HY, Liang P. Diagnostic value of two-dimensional shear wave elastography in papillary thyroid microcarcinoma. Onco Targets Ther. 2016; 9:1311–7.
20). Wang F, Chang C, Gao Y, Chen YL, Chen M, Feng LQ. Does shear wave elastography provide additional value in the evaluation of thyroid nodules that are suspicious for malignancy? J Ultrasound Med. 2016; 35(11):2397–404.
Article
21). Liu B, Liang J, Zheng Y, Xie X, Huang G, Zhou L, et al. Two-dimensional shear wave elastography as promising diagnostic tool for predicting malignant thyroid nodules: a prospective single-centre experience. Eur Radiol. 2015; 25(3):624–34.
Article
22). Park AY, Son EJ, Han K, Youk JH, Kim JA, Park CS. Shear wave elastography of thyroid nodules for the prediction of malignancy in a large scale study. Eur J Radiol. 2015; 84(3):407–12.
Article
23). Kim H, Kim JA, Son EJ, Youk JH. Quantitative assessment of shear-wave ultrasound elastography in thyroid nodules: diagnostic performance for predicting malignancy. Eur Radiol. 2013; 23(9):2532–7.
Article
24). Veyrieres JB, Albarel F, Lombard JV, Berbis J, Sebag F, Oliver C, et al. A threshold value in shear wave elastography to rule out malignant thyroid nodules: a reality? Eur J Radiol. 2012; 81(12):3965–72.
Article
25). Kwak JY, Kim EK. Diagnostic performance of quantitative shear wave ultrasound elastography for thyroid cancer. J Korean Thyroid Assoc. 2011; 4(2):109–13.
26). Sebag F, Vaillant-Lombard J, Berbis J, Griset V, Henry JF, Petit P, et al. Shear wave elastography: a new ultrasound imaging mode for the differential diagnosis of benign and malignant thyroid nodules. J Clin Endocrinol Metab. 2010; 95(12):5281–8.
Article
27). Xing P, Chen Q, Yang ZW, Liu CB, Wu CJ. Combination of conventional ultrasound and tissue quantification using acoustic radiation force impulse technology for differential diagnosis of small thyroid nodules. Int J Clin Exp Med. 2016; 9(5):8288–95.
28). Zhang YF, Xu JM, Xu HX, Liu C, Bo XW, Li XL, et al. Acoustic radiation force impulse elastography: a useful tool for differential diagnosis of thyroid nodules and recommending fine-needle aspiration: a diagnostic accuracy study. Medicine (Baltimore). 2015; 94(42):e1834.
29). Zhang YF, Xu HX, Xu JM, Liu C, Guo LH, Liu LN, et al. Acoustic radiation force impulse elastography in the diagnosis of thyroid nodules: useful or not useful? Ultrasound Med Biol. 2015; 41(10):2581–93.
Article
Full Text Links
  • IJT
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr