Asian Spine J.  2018 Aug;12(4):662-668. 10.31616/asj.2018.12.4.662.

Efficacy of Anal Needle Electrodes for Intraoperative Spinal Cord Monitoring with Transcranial Muscle Action Potentials

Affiliations
  • 1Department of Orthopedic Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan. imagama@med.nagoya-u.ac.jp
  • 2Department of Orthopaedic Surgery, Japanese Red Cross Nagoya Daiichi Hospital, Nagoya, Japan.
  • 3Department of Orthopaedic Surgery, Hamamatsu University School of Medicine, Hamamatsu, Japan.

Abstract

STUDY DESIGN: Retrospective study. PURPOSE: To examine the relationship between postoperative bowel bladder disorder (BBD) and the efficacy of needle electrodes for the external anal sphincter (EAS) in intraoperative spinal cord monitoring with transcranial muscle action potentials (Tc-MsEP). OVERVIEW OF LITERATURE: Spinal surgery for spina bifida, spinal cord tumor, and spinal tethered cord syndrome has a high rate of postoperative BBD. Monitoring of the EAS with Tc-MsEP is frequently performed during spinal surgery. We initially used plug-surface electrodes for this purpose, but have more recently switched to needle electrodes for the monitoring of the EAS. To date, there has been no comparison between the utility of these electrodes.
METHODS
Waveform derivation, exacerbation of postoperative BBD, and sensitivity and specificity for prediction of BBD by 70% amplitude reduction of EAS activity using needle and plug-surface electrodes were investigated in 239 spine surgeries. The cut-off for the % drop in amplitude for BBD prediction was determined for EAS monitoring using a needle electrode.
RESULTS
The overall rate of postoperative BBD aggravation was 7.1% (17/239 cases), with the individual rates using needle and plug-surface electrodes being 6.9% (8/116) and 7.3% (9/123), respectively. The waveform derivation rate was significantly higher using needle electrodes (91.3% [106/116] vs. 76.4% [94/123], p <0.01). In patients with baseline waveform detection, the sensitivity and specificity for postoperative BBD were similar in the two groups. With needle electrodes, a cutoff amplitude of Tc-MsEP for the EAS at the end of surgery of 25% of the baseline amplitude had a sensitivity of 89% and specificity of 82% for the prediction of postoperative BBD aggravation.
CONCLUSIONS
The significantly higher waveform derivation rate using needle electrodes suggests that these electrodes are effective for monitoring the EAS in spinal surgery in cases with preoperative BBD.

Keyword

Anal sphincter; Motor evoked potential; Electrode; Motor deficit; Spine

MeSH Terms

Action Potentials*
Anal Canal
Electrodes*
Evoked Potentials, Motor
Humans
Needles*
Neural Tube Defects
Retrospective Studies
Sensitivity and Specificity
Spinal Cord Neoplasms
Spinal Cord*
Spinal Dysraphism
Spine
Urinary Bladder
Full Text Links
  • ASJ
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr