Korean J Thorac Cardiovasc Surg.  2014 Aug;47(4):367-372.

Efficacy of Cox Maze IV Procedure Using Argon-Based Cryoablation: A Comparative Study with N2O-Based Cryoablation

Affiliations
  • 1Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine, Korea. kkh726@snu.ac.kr
  • 2Department of Thoracic and Cardiovascular Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Korea.

Abstract

BACKGROUND
We compared the mid-term results of the Cox maze IV procedure using argon-based cryoablation with a procedure using N2O-based cryoablation.
METHODS
From May 2006 to June 2012, 138 patients (mean age, 58.2+/-11.0 years) underwent the Cox maze IV procedure. Eighty-five patients underwent the maze procedure using an N2O-based cryoprobe (group N), and 53 patients underwent the maze procedure using an argon-based cryoprobe (group A). Bipolar radiofrequency ablation was concomitantly used in 131 patients. The presence of atrial fibrillation immediately, 6 months, 1 year, and 2 years after surgery was compared.
RESULTS
Early mortality occurred in 6 patients (4.3%). There were no differences in early mortality or postoperative complications between the two groups. Nineteen of 115 patients (16.5%) remained in atrial fibrillation at postoperative 12 months (14 of 80 patients (17.5%) in group N and 5 of 35 patients (14.3%) in group A, p=0.669). There were no differences in the number of patients who remained in atrial fibrillation at any of the time periods except in the immediate postoperative period. A multivariable analysis revealed that the energy source of cryoablation was not associated with the presence of atrial fibrillation at 1 year (p=0.862) and that a fine F wave (<0.1 mV) was the only risk factor predicting the presence of atrial fibrillation at 1 year (p<0.001, odds ratio=20.287).
CONCLUSION
The Cox maze IV procedure using an argon-based cryoprobe was safe and effective compared with the maze procedure using an N2O-based cryoprobe in terms of operative outcomes and the restoration of sinus rhythm for up to 2 years after surgery.

Keyword

Arrhythmia surgery; Arrhythmia; Atrial fibrillation; Ablation; Cryosurgery

MeSH Terms

Arrhythmias, Cardiac
Atrial Fibrillation
Catheter Ablation
Cryosurgery*
Humans
Mortality
Postoperative Complications
Postoperative Period
Risk Factors
Full Text Links
  • KJTCS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr