Korean J Thorac Cardiovasc Surg.  2008 Dec;41(6):710-717.

The Long-term Results of a Modified Maze Procedure with Using Cryoablation

Affiliations
  • 1Department of Thoracic and Cardiovascular Surgery, Dong-A University Hospital, Dong-A University College of Medicine, Korea. jswoo@daunet.donga.ac.kr

Abstract

BACKGROUND: Atrial fibrillation is associated with several complications such as cerebro-vascular accidents and peripheral arterial embolism. Most of the patients who have this arrhythmia chronically feel their heart beating and so they are frightened; therefore, the quality of a patient's life is decreased. The purpose of this article is to determine the long term results of a modified Maze procedure and the factors that influence the success of the procedure. MATERIAL AND METHOD: This study enrolled 88 patients who underwent the modified Maze with using cryoablation between June, 2001 and February, 2007. The 88 consecutive patients were divided into two groups according to how the pulmonary veins were isolated, that is, with or without cryoablation. There were 58 patients who were isolated by cutting and sewing in the right pulmonary veins and by cyroablation in the left pulmonary veins in group 1 (group 1, n=58), and 30 patients who underwent isolation by cryoablation in the right & left pulmonary veins were placed in group 2 (group 2, n=30). The ECG was checked at discharge to determine the sinus conversion rate and we followed up the patients to determine whether or not the patients maintained sinus rhythm. We also checked the ECG at the last visit to determine the patients' heart rhythm. RESULT: The mean follow up time was 44.3+/-19.2 months. At discharge, 72.4% of the patients in group 1 were in proper sinus rhythm and 66.7% of the patients in group 2 were in proper sinus rhythm. At the last follow up, 81% of the patients in group 1 were in normal sinus rhythm and 60% of the patients in group 2 were in normal sinus rhythm. When we analyzed the data via the Kaplan-Meier method, 86.5% of the patients were free from atrial fibrillation (% free from AF) at 1 year, 80% of the patients were free from atrial fibrillation at 5 year in group 1 and 70% of the patients were free from atrial fibrillation at 1 year and 51% of the patients in group 2 were free from atrial fibrillation at 5 year. CONCLUSION: The modified Maze technique using cryoablation was a simple and effective procedure. But the success rate of the Maze technique using cryoblation is lower than that of the standard Maze III. The method using cryoablation shorten the operation time, but we must conduct more studies to get a better result of the modified Maze technique with using cryoablation.

Keyword

Atrial fibrillation; Cryoablation; Arrhythmia surgery

MeSH Terms

Arrhythmias, Cardiac
Atrial Fibrillation
Cryosurgery
Electrocardiography
Embolism
Follow-Up Studies
Heart
Humans
Pulmonary Veins
Full Text Links
  • KJTCS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr