1. Maryam R, Gregory JA, Mocco J. Early history of the stereotactic apparatus in neurosurgery. Neurosurg Focus. 2009; 27:E12.
2. Kondziolka D, Lunsford LD, Leksell D. Stereotactic frame systems: The Leksell stereotactic system. In : Alexander E, Maciunas RJ, editors. Advanced Neurosurgical Navigation. New York: Thieme Medical Publishers;1999. p. 233–241.
3. Dorward NL, Thomas DGT. Stereotactic frame systems: The Brown-Roberts-Wells and Cosman-Roberts-Wells systems. In : Alexander E, Maciunas RJ, editors. Advanced Neurosurgical Navigation. New York: Thieme Medical Publishers;1999. p. 243–253.
4. Zamorano L. The Zamorano-Dujovny multipurpose localizing unit. In : Alexander E, Maciunas RJ, editors. Advanced Neurosurgical Navigation. New York: Thieme Medical Publishers;1999. p. 255–266.
5. Najarian S, Fallahnezhad M, Afshari E. Advances in medical robotic systems with specific applications in surgery – a review. J Med Eng Technol. 2011; 35:26–37.
6. Kwoh YS, Hou J, Jonckheere EA, Hayati S. A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgery. IEEE Trans Biomed Eng. 1988; 35:153–160.
Article
8. Sam Eljamel M. Robotic Applications in Neurosurgery. In : Bozovic V, editor. Medical Robotics. InTech;2008. p. 41–64.
9. Li QH, Zamorano L, Pandya A, Perez R, Gong J, Diaz F. The application accuracy of the NeuroMate robot – a quantitative comparison with frameless and frame-based surgical localization systems. Computer Aided Surgery. 2002; 7:90–98.
Article
10. Kajita Y, Nakatsubo D, Kataoka H, Nagai T, Nakura T, Wakabayashi T. Installation of a Neuromate Robot for Stereotactic Surgery: Efforts to Conform to Japanese Specifications and an Approach for Clinical Use – Technical Notes. Neurol Med Chir. 2015; 55:907–914.
Article
14. Joskowicz L, Shamir R, Israel Z, Shoshan Y, Shoham M. Renaissance robotic system for keyhole cranial neurosurgery: in-vivo accuracy study. In : Proceedings of the Simposio Mexicano en Ciruga Asistida por Computadora y Procesamiento de Imgenes Mdicas (MexCAS '11); 2011.
15. Devito DP, Kaplan L, Dietl R, Pfeiffer M, Horne D, Silberstein B, et al. Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: retrospective study. Spine. 2010; 35:2109–2115.
Article
16. Leksell L. Stereotactic radiosurgery. J Neurol Neurosurg Psychiatry. 1983; 46:797–803.
Article
18. Gagnon GJ, Nasr NM, Liao JJ, Molzahn I, Marsh D, McRae D, et al. Treatment of spinal tumors using CyberKnife fractionated stereotactic radiosurgery: pain and quality-of-life assessment after treatment in 200 patients. Neurosurgery. 2009; 64:297–306.
19. Inoue M, Sato K, Koike I. An Analysis of the Accuracy of the 6D Tracking With CyberKnife. Int J Radiat Oncol Biol Phys. 2006; 66:Suppl. S611.
20. Schweikard A, Shiomi H, Adler J. Respiration tracking in radiosurgery. Med Phys. 2004; 31:2738–2741.
Article
22. Wurm RE, Erbel S, Schwenkert I, Gum F, Aqaoglu D, Schild R, et al. Novalis frameless image-guided noninvasive radiosurgery: initial experience. Neurosurgery. 2008; 62:A11–A17.
23. Abacioglu MU. Advances in Technology in Radiation Oncology. Eur Assoc Neurooncol Mag. 2012; 2:11–14.