J Adv Prosthodont.  2016 Aug;8(4):313-320. 10.4047/jap.2016.8.4.313.

Clinical evaluation of mandibular implant overdentures via Locator implant attachment and Locator bar attachment

Affiliations
  • 1Prosthodontics, Dental Research Insititute, Pusan Natinal University Dental Hospital, Yangsan, Republic of Korea. huhjb@pusan.ac.kr

Abstract

PURPOSE
The aim of this study was to evaluate the clinical findings and patient satisfaction on implant overdenture designed with Locator implant attachment or Locator bar attachment in mandibular edentulous patients.
MATERIALS AND METHODS
Implant survival rate, marginal bone loss, probing depth, peri-implant inflammation, bleeding, plaque, calculus, complications, and satisfaction were evaluated on sixteen patients who were treated with mandibular overdenture and have used it for at least 1 year (Locator implant attachment: n=8, Locator bar attachment: n=8).
RESULTS
Marginal bone loss, probing depth, plaque index of the Locator bar attachment group were significantly lower than the Locator implant attachment group (P<.05). There was no significant difference on bleeding, peri-implant inflammation, and patient satisfaction between the two denture types (P>.05). The replacement of the attachment components was the most common complication in both groups. Although there was no correlation between marginal bone loss and plaque index, a significant correlation was found between marginal bone loss and probing depth.
CONCLUSION
The Locator bar attachment group indicates lesser marginal bone loss and need for maintenance, as compared with the Locator implant attachment group. This may be due to the splinting effect among implants rather than the types of Locator attachment.

Keyword

Implant overdenture; Edentulous mandible; Locator implant attachment; Locator bar attachment; Clinical complication

MeSH Terms

Calculi
Denture, Overlay*
Dentures
Hemorrhage
Humans
Inflammation
Patient Satisfaction
Splints
Survival Rate

Figure

  • Fig. 1 Intraoral view of implant overdenture attachment. (A) LIA group: Locator implant attachment utilized with two implants, (B) LBA group: Locator bar attachment utilized with four implants splinted with a bar.


Reference

1. van Waas MA. The influence of clinical variables on patients' satisfaction with complete dentures. J Prosthet Dent. 1990; 63:307–310.
2. Melas F, Marcenes W, Wright PS. Oral health impact on daily performance in patients with implant-stabilized overdentures and patients with conventional complete dentures. Int J Oral Maxillofac Implants. 2001; 16:700–712.
3. Awad MA, Lund JP, Shapiro SH, Locker D, Klemetti E, Chehade A, Savard A, Feine JS. Oral health status and treatment satisfaction with mandibular implant overdentures and conventional dentures: a randomized clinical trial in a senior population. Int J Prosthodont. 2003; 16:390–396.
4. Batenburg RH, Meijer HJ, Raghoebar GM, Vissink A. Treatment concept for mandibular overdentures supported by endosseous implants: a literature review. Int J Oral Maxillofac Implants. 1998; 13:539–545.
5. Feine JS, Carlsson GE, Awad MA, Chehade A, Duncan WJ, Gizani S, Head T, Heydecke G, Lund JP, MacEntee M, Mericske-Stern R, Mojon P, Morais JA, Naert I, Payne AG, Penrod J, Stoker GT, Tawse-Smith A, Taylor TD, Thomason JM, Thomson WM, Wismeijer D. The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Gerodontology. 2002; 19:3–4.
6. Schneider AL, Kurtzman GM. Bar overdentures utilizing the Locator attachment. Gen Dent. 2001; 49:210–214.
7. Trakas T, Michalakis K, Kang K, Hirayama H. Attachment systems for implant retained overdentures: a literature review. Implant Dent. 2006; 15:24–34.
8. Mericske-Stern RD, Zarb GA. Clinical protocol for treatment with implant-supported overdentures. In : Bolender CE, Zarb GA, Carlsson GE, editors. Boucher's Prosthodontic Treatment for Edentulous Patients. St. Louis: Mosby;1997. p. 527.
9. Burns DR. Mandibular implant overdenture treatment: consensus and controversy. J Prosthodont. 2000; 9:37–46.
10. Schneider AL. The use of a self-aligning, low-maintenance overdenture attachment. Dent Today. 2000; 19:24. 26.
11. Kim MS, Yoon MJ, Huh JB, Jeon YC, Jeong CM. Implant overdenture using a locator bar system by drill and tapping technique in a mandible edentulous patient: a case report. J Adv Prosthodont. 2012; 4:116–120.
12. Technique manual Locator bar attachment system. accessed on 9 December 2015. Available at: http://www.zestanchors.com/media/wysiwyg/pdf/locator/L8003-TM_REV_G_03-14_tech_manual_only.pdf.
13. Vere J, Hall D, Patel R, Wragg P. Prosthodontic maintenance requirements of implant-retained overdentures using the locator attachment system. Int J Prosthodont. 2012; 25:392–394.
14. Wang F, Monje A, Huang W, Zhang Z, Wang G, Wu Y. Maxillary four implant-retained overdentures via locator® attachment: Intermediate-term results from a retrospective study. Clin Implant Dent Relat Res. 2016; 18:571–579.
15. Mackie A, Lyons K, Thomson WM, Payne AG. Mandibular two-implant overdentures: three-year prosthodontic maintenance using the locator attachment system. Int J Prosthodont. 2011; 24:328–331.
16. Akça K, Çavuşoğlu Y, Sağirkaya E, Çehreli MC. Early-loaded one-stage implants retaining mandibular overdentures by two different mechanisms: 5-year results. Int J Oral Maxillofac Implants. 2013; 28:824–830.
17. Krennmair G, Seemann R, Fazekas A, Ewers R, Piehslinger E. Patient preference and satisfaction with implant-supported mandibular overdentures retained with ball or locator attachments: a crossover clinical trial. Int J Oral Maxillofac Implants. 2012; 27:1560–1568.
18. Cochran DL, Buser D, ten Bruggenkate CM, Weingart D, Taylor TM, Bernard JP, Peters F, Simpson JP. The use of reduced healing times on ITI implants with a sandblasted and acid-etched (SLA) surface: early results from clinical trials on ITI SLA implants. Clin Oral Implants Res. 2002; 13:144–153.
19. Yoo HS, Kang SN, Jeong CM, Yoon MJ, Huh JB, Jeon YC. Effects of implant collar design on marginal bone and soft tissue. J Korean Acad Prosthodont. 2012; 50:21–28.
20. Quirynen M, Naert I, van Steenberghe D, Teerlinck J, Dekeyser C, Theuniers G. Periodontal aspects of osseointegrated fixtures supporting an overdenture. A 4-year retrospective study. J Clin Periodontol. 1991; 18:719–728.
21. Loe H, Silness J. Periodontal disease in pregnancy I. Prevalence and severity. Acta Odontol Scand. 1963; 21:533–551.
22. Mombelli A, van Oosten MA, Schurch E Jr, Land NP. The microbiota associated with successful or failing osseointegrated titanium implants. Oral Microbiol Immunol. 1987; 2:145–151.
23. Likert R. A technique for the measurement of attitudes. Arch Psychol. 1932; 22:140–155.
24. Pan S, Awad M, Thomason JM, Dufresne E, Kobayashi T, Kimoto S, Wollin SD, Feine JS. Sex differences in denture satisfaction. J Dent. 2008; 36:301–308.
25. Vervoorn JM, Duinkerke AS, Luteijn F, van de Poel AC. Assessment of denture satisfaction. Community Dent Oral Epidemiol. 1988; 16:364–367.
26. Bergendal T, Engquist B. Implant-supported overdentures: a longitudinal prospective study. Int J Oral Maxillofac Implants. 1998; 13:253–262.
27. Krennmair G, Krainhöfner M, Piehslinger E. Implant-supported mandibular overdentures retained with a milled bar: a retrospective study. Int J Oral Maxillofac Implants. 2007; 22:987–994.
28. Lindquist LW, Rockler B, Carlsson GE. Bone resorption around fixtures in edentulous patients treated with mandibular fixed tissue-integrated prostheses. J Prosthet Dent. 1988; 59:59–63.
29. Gotfredsen K, Holm B. Implant-supported mandibular overdentures retained with ball or bar attachments: a randomized prospective 5-year study. Int J Prosthodont. 2000; 13:125–130.
30. Lekholm U, Adell R, Lindhe J, Brånemark PI, Eriksson B, Rockler B, Lindvall AM, Yoneyama T. Marginal tissue reactions at osseointegrated titanium fixtures. (II) A cross-sectional retrospective study. Int J Oral Maxillofac Surg. 1986; 15:53–61.
31. Quirynen M, van Steenberghe D, Jacobs R, Schotte A, Darius P. The reliability of pocket probing around screw-type implants. Clin Oral Implants Res. 1991; 2:186–192.
32. Walton JN, Huizinga SC, Peck CC. Implant angulation: a measurement technique, implant overdenture maintenance, and the influence of surgical experience. Int J Prosthodont. 2001; 14:523–530.
33. Kuoppala R, Näpänkangas R, Raustia A. Outcome of implant-supported overdenture treatment-a survey of 58 patients. Gerodontology. 2012; 29:e577–e584.
34. Pasciuta M, Grossmann Y, Finger IM. A prosthetic solution to restoring the edentulous mandible with limited interarch space using an implant-tissue-supported overdenture: a clinical report. J Prosthet Dent. 2005; 93:116–120.
35. Meijer HJ, Starmans FJ, Steen WH, Bosman F. Location of implants in the interforaminal region of the mandible and the consequences for the design of the superstructure. J Oral Rehabil. 1994; 21:47–56.
Full Text Links
  • JAP
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr