J Korean Ophthalmol Soc.  2001 May;42(5):783-787.

A Case of Medpor(R) Orbital Implant Infection

Affiliations
  • 1Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Korea.

Abstract

PURPOSE: Porous orbital implant Medpor(R) which is made of polyethylene is being widely used currently. Compared with previously used porous orbital implants, it is somewhat preferred due to cheaper and easier usage but reports on its postoperative complications are not sufficient. We report the first case of Medpor(R) infection developed domestically.
METHODS
A 20 year-old male patient was admitted with Medpor(R) infection 14 months after Medpor(R) orbital implant insertion. He was treated with antibiotics.
RESULTS
Infection was controlled with antibiotics without implant removal. Implant exposure occurred after infection control so dermis graft was done.

Keyword

Dermis graft; Implant exposure; Medpor(R) infection

MeSH Terms

Anti-Bacterial Agents
Dermis
Humans
Infection Control
Male
Orbit*
Orbital Implants*
Polyethylene
Postoperative Complications
Transplants
Young Adult