J Korean Acad Rehabil Med.  1999 Aug;23(4):809-814.

Correlation of Ultrasonographic Measure of Lumbar Multifidus Muscles with Isometric Torque of Low Back

Affiliations
  • 1Department of Rehabilitation Medicine, Seoul National University College of Medicine.
  • 2Department of Rehabilitation Medicine, Dan-guk University College of Medicine.

Abstract


OBJECTIVE
To measure lumbar multifidus muscles by ultrasonography and to study its correlation with the isometric peak touque of back. METHOD: Bilateral L5 and S1 multifidus muscle sizes of 18 healthy volunteers were measured in prone position by ultrasonography with 7.5 MHz, 40 mm-length probe. Multifidus muscles were identified using anatomic landmark-spinous process and lamina and vertical and horizontal diameter were measured. Boundary of muscle was traced and cross sectional area was measured. Lumbar spinal range of motion (ROM) and isometric peak torque of three axes-flexion/ extension, rotation and lateral flexion-were measured by Isostation B-200R back muscle tester.
RESULTS
Multifidus muscle cross sectional areas were well correlated with isometric peak torque in all direction of movements. Muscle size and lumbar spine ROM showed no correlation.
CONCLUSION
Ultrasonographic measure of lumbar multifidus muscles could be a useful tool to estimate back muscle function.

Keyword

Ultrasonography; Back muscle; Multifidus

MeSH Terms

Back Muscles
Healthy Volunteers
Muscles*
Paraspinal Muscles*
Prone Position
Range of Motion, Articular
Spine
Torque*
Ultrasonography
Full Text Links
  • JKARM
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr