J Korean Soc Plast Reconstr Surg.  2008 Jul;35(4):423-430.

CT Number Measurement of Residual Foreign Bodies in Face

Affiliations
  • 1Department of Plastic and Reconstructive Surgery, College of Medicine, Soon Chun Hyang University, Kyunsangbuk-do, Korea. medi619@hanmail.net

Abstract

PURPOSE: Computed tomography theoretically should improve detection of foreign bodies and provide more information of adjacent soft tissues. And the CT scanner and PACS program proved to be an excellent instrument for detection and localization of most facial foreign bodies above certain minimum levels of detectability. The severity of injury in penetrating trauma to the face, it is often underestimated by physical examination. Diagnosis of a retained foreign object is always critical.
METHODS
From March, 2005 to February 2008 a study was done with 200 patients who had facial trauma. Axial and coronal CT images were obtained with a General Electric(Milwaukee, Wis) 9800 CT scanner at 130kV, 90mA, with a 2-mm section thickness and a 512x512 matrix.
RESULTS
Axial and coronal CT images at various window widths should be used as the first imaging modality to detect facial foreign bodies. The attenuation coefficients for the metallic and nonmetallic foreign bodies ranged from -437 to +3071 HU. As a general rule, metallic foreign bodies produced more Hounsfield artifacts than nonmetallic foreign bodies, thus providing a clue to their composition. All of the metallic foreign bodies were represented by a single peak and had a maximum attenuation coefficient of +3071 HU. Of the nonmetallic foreign bodies, glass had an attenuation coefficient that ranged from +105 to +2039, while plastic had a much lower coefficient that ranged from -62 to -35. wood had the lowest range of attenuation coefficients: -491 to -437.
CONCLUSION
The PACS program allows one to distinguish metallic from nonmetallic foreign bodies and to individually identify the specific composition of many nonmetallic foreign bodies. This program does not, however, allow identification of the specific composition of a metallic foreign body. We recommend this type of software program for CT scanning of any patient with an injury to the face in which a foreign body is suspected.

Keyword

CT; Foreign body; Attenuation coefficient; Hounsfield unit

MeSH Terms

Artifacts
Foreign Bodies
Glass
Humans
Physical Examination
Plastics
Wood
Plastics