J Korean Acad Prosthodont.
2007 Aug;45(4):492-505.
Removal torque and bone formation of orthodontic miniscrew implant
- Affiliations
-
- 1Major in Dentistry, Department of Medical Science, Graduate School, Korea University, Korea. yunyudc@yahoo.com
Abstract
-
STATEMENT OF PROBLEM: An orthodontic miniscrew implant has been used as a skeletal anchorage for orthodontic treatment. However, any relation among the influence of the cortical bone, morphologic differences of orthodontic miniscrew implants and new bone formation hasn't been made clear yet.
PURPOSE: The purpose of this study was to evaluate whether the orthodontic miniscrew implant could work as an intraoral skeletal anchorage immediately and stably for orthodontic treatment after insertion of it.
MATERIAL AND METHODS: Two types of orthodontic miniscrew implants were used in this experiment; tapered type and straight type. One hundred and sixty eight orthodontic miniscrew implants were inserted into the tibiae of 21 rabbits and sacrificed on 3, 7, 11, 14, 21 and 28days later after insertion of them to study removal torque values and histologic and histomorphometric analyses.
RESULTS
The results were as follows.
1. The removal torque values of the tapered type were higher than those of the straight type in all groups(p<0.05).
2. There wasn't any distinguishing differences between the tapered type and the straight type about the new bone formation percentage.
3. The removal torque values for both the tapered type and the straight type were gradually decreased at early stages of the test but started to increase at the 7 days group of the straight type and the 11 days group of the tapered type.
4. New bone formation percentage was increased gradually for both the tapered and the straight types as time passed(p<0.05).
5. It was found that the tapered type showed lower values in the cortical bone about both the maximum equilibratory stress distribution and the maximum principal stress distribution than the straight type in linear finite elements analysis.
CONCLUSION
According to the research, the removal torque values were decreased at 7 days group of the tapered type and 11 days group of the straight type after the insertion of the orthodontic miniscrew implants in tibiae of rabbits. Considering the human bone activity, it is better to apply the orthodontic force 3.4 weeks later than to apply it immediately after the insertion of orthodontic miniscrew implants. Considering that general orthodontic force is about 250.500 grams, the tapered type can be worked as a stable skeletal anchorage in an orthodontic treatment even if the orthodontic force is applied on it immediately after the insertion of it.