An 86 year old woman was admitted complaining of dyspnea and right pleuritic pain with a 5 week durations. A physical examination, chest X-ray, and diagnostic thoracentesis upon admission revealed findings consistent with severe pneumonia and empyema on the right lung. Despite the insertion of a chest tube and negative suction via Emersion pump, the continuous air leakage was sustained, and a bronchopleural fistula (BPF) was found on the chest-CT. A flexible bronchoscopic occlusion with an Endobronchial Watanabe Spigot (EWS) was performed after 56 days of admission. An 5 mm diameter EWS was successfully inserted into the anterior segmental bronchus of the right upper lobe by flexible bronchoscope. There was no aAir leakage detected after this procedure. The patient was discharged 30 days after the EWS occlusion.

Keyword

Bronchopleural fistula; Flexible bronchoscope; EWS

MeSH Terms

Aged, 80 and over
Bronchi
Bronchoscopes*
Chest Tubes
Dyspnea
Empyema
Female
Fistula*
Humans
Lung
Physical Examination
Pneumonia
Suction
Thorax
Full Text Links
  • TRD
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr