1. Ding J, Gutmann JL, Fan B, Lu Y, Chen H. Investigation of apex locators and related morphological factors. J Endod. 2010. 36:1399–1403.
Article
2. Ricucci D, Langeland K. Apical limit of root canal instrumentation and obturation, part 2. a histological study. Int Endod J. 1998. 31:394–409.
Article
3. Suzuki K. Experimental study on iontophoresis. J Jpn Stomatol. 1942. 16:411–417.
4. Sunada I. New method for measuring the length of the root canal. J Dent Res. 1962. 41:375–387.
Article
5. Kobayashi C, Suda H. New electronic canal measuring device based on the ratio method. J Endod. 1994. 20:111–114.
Article
6. Kobayashi C. Electronic canal length measurement. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1995. 79:226–231.
Article
7. Green D. Stereomicroscopic study of 700 root apices of maxillary and mandibular posterior teeth. Oral Surg Oral Med Oral Pathol. 1960. 13:728–733.
Article
8. Dummer PM, McGinn JH, Rees DG. The position and topography of the apical canal constriction and apical foramen. Int Endod J. 1984. 17:192–198.
Article
9. Kuttler Y. Microscopic investigation of root apexes. J Am Dent Assoc. 1955. 50:544–552.
Article
10. Torabinejad M, Walton RE. Endodontics: principles and practice. 2009. 4th ed. Missouri: Saunders Elsevier;29–34.
11. Herrera M, Abalos C, Planas AJ, Llamas R. Influence of apical constriction diameter on Root ZX apex locator precision. J Endod. 2007. 33:995–998.
Article
12. Stein TJ, Corcoran JF, Zillich RM. Influence of the major and minor foramen diameters on apical electronic probe measurements. J Endod. 1990. 16:520–522.
13. Fouad AF, Rivera EM, Krell KV. Accuracy of the Endex with variations in canal irrigants and foramen size. J Endod. 1993. 19:63–67.
Article
14. Huang L. An experimental study of the principle of electronic root canal measurement. J Endod. 1987. 13:60–64.
Article
15. Hachmeister DR, Schindler WG, Walker WA 3rd, Thomas DD. The sealing ability and retention characteristics of mineral trioxide aggregate in a model of apexification. J Endod. 2002. 28:386–390.
Article
16. Cho JH, Kum KY, Lee SJ.
In vitro evaluation of accuracy and consistency of four different electronic apex locators. J Korean Acad Conserv Dent. 2006. 31:390–397.
Article
17. Ponce EH, Vilar Fernández JA. The cemento-dentino-canal junction, the apical foramen, and the apical constriction: evaluation by optical microscopy. J Endod. 2003. 29:214–219.
Article
18. Sjogren U, Hägglund B, Sundqvist G, Wing K. Factors affecting the long-term results of endodontic treatment. J Endod. 1990. 16:498–504.
Article
19. Pagavino G, Pace R, Baccetti T. A SEM study of in vivo accuracy of the Root ZX electronic apex locator. J Endod. 1998. 24:438–441.
20. Goldberg F, De Silvio AC, Manfré S, Nastri N.
In vitro measurement accuracy of an electronic apex locator in teeth with simulated apical root resorption. J Endod. 2002. 28:461–463.
Article
21. Nguyen HQ, Kaufman AY, Komorowski RC, Friedman S. Electronic length measurement using small and large files in enlarged canals. Int Endod J. 1996. 29:359–364.
Article
22. Kim BH, Lee YK, Kim YS. A study on the accuracy of the ROOT-ZX in the canal with mechanically formed constriction. J Korean Acad Conserv Dent. 1999. 24:628–632.
23. Czerw RJ, Fulkerson MS, Donnelly JC. An
in vitro test of a simplified model to demonstrate the operation of electronic root canal measuring devices. J Endod. 1994. 20:605–606.
Article
24. Cho YL, Son WH, Hwang HK. An accuracy of the several electronic apex locators on the mesial root canal of the mandibular molar. J Korean Acad Conserv Dent. 2005. 30:477–485.
Article
25. Lee SJ, Nam KC, Kim YJ, Kim DW. Clinical accuracy of a new apex locator with an automatic compensation circuit. J Endod. 2002. 28:706–709.
Article
26. Ounsi HF, Naaman A.
In vitro evaluation of the reliability of the Root ZX electronic apex locator. Int Endod J. 1999. 32:120–123.
Article
27. Mayeda DL, Simon JH, Aimar DF, Finley K.
In vivo measurement accuracy in vital and necrotic canals with the Endex apex locator. J Endod. 1993. 19:545–548.
Article
28. Herrera M, Abalos C, Planas AJ, Llamas R. Influence of apical constriction diameter on Root ZX apex locator precision. J Endod. 2007. 33:995–998.
Article
29. Shabahang S, Goon WW, Gluskin AH. An in vivo evaluation of Root ZX electronic apex locator. J Endod. 1996. 22:616–618.
30. Tselnik M, Baumgartner JC, Marshall JG. An evaluation of root ZX and elements diagnostic apex locators. J Endod. 2005. 31:507–509.
Article
31. Meredith N, Gulabivala K. Electrical impedance measurements of root canal length. Endod Dent Traumatol. 1997. 13:126–131.
Article
32. Nekoofar MH, Ghandi MM, Hayes SJ, Dummer PM. The fundamental operating principles of electronic root canal length measurement devices. Int Endod J. 2006. 39:595–609.
Article
33. Berman LH, Fleischman SB. Evaluation of the accuracy of the Neosono-D electronic apex locator. J Endod. 1984. 10:164–167.
Article
34. Saito T, Yamashita Y. Electronic determination of root canal length by newly developed measuring device. Influences of the diameter of apical foramen, the size of K-file and the root canal irrigants. Dent Jpn (Tokyo). 1990. 27:65–72.
35. Huang L. An experimental study of the principle of electronic root canal measurement. J Endod. 1987. 13:60–64.
Article
36. ElAyouti A, Weiger R, Löst C. Frequency of overinstrumentation with an acceptable radiographic working length. J Endod. 2001. 27:49–52.
Article