Korean Lepr Bull.  2011 Dec;44(1):71-84.

A Study on the fabrication request for the removable partial denture framework

Affiliations
  • 1National Sorokdo Hospital, Gwang Yang Health College, Korea.

Abstract

The purpose of this study was to investgate and evaluate whether the recording information contained in the work authorization was performed properly and master casts were designed accurately according to the rationale and principles of the removable partial denture when the work authorization and the master casts were sent to the dental framework. the accurate recording of the work authorization sent to dental laboratory in Hwasun for removable partial denture framework, the normal form of the occlusal rest guiding plan of the surveyed crown using the surveyor, the location analysis of the occlusal rest seat, the design patten of the maxillary and mandibulary major connectors, the use of the surveyor on the master cast, the status of the secondary impression taken in the distal extension edentulous areas were investigated for this study. The following results were obtained : 1. In the status of the occlusal rest seat prepared in the abutment, the occlusal rest seat with normal form was 81.25%, 95.45%, that without form was 6.25%, 0.00%, respectively in Class I and Class II on the maxillary cast and the occlusal rest seat with normal form was 76.92%, 95.45%, that without form was 7.69%, 0.00% respectively in Class I and Class II on the mandibular cast. 2. In the status of the guiding plan, the guiding plan with the normal form was 79.17%, 86.36% that with abnormal form was 20.84%, 13.64% respectively in Class I and Class II on the maxillary cast and the guiding plan with normal form was 79.49%, 77.27%, that with abnormal form was 20.51%, 22.73% respectively in Class I and Class II on the mandibular cast. 3. The abutment splinting in the distal extension removable partial denture was 20.78%, 27.27%, respectively in Class I and Class II on the maxillary cast and was 25.64%, 13.64% respectively in Class I and Class II on the mandibular cast. 4. The location and form of the major connector delineated on the maxillary and mandibular master cast was 95.83%, 98.41% respectively. 5. The delineation and recording on the work authorization was incomplete as group II(73.33%), group I(14.07%), group III(12.59%) and group IV (0.00%) in investigating the contents of the work authorization. 6. Aker's clasp of the types of the direct retainer was nots used 72.22%, 74.60%, in the maxillary and mandibular casts respectively. 7. The location of the indirect retainer delineated on the maxillary and mandibular master cast was 51.43%, 50.82% respectively. 8. The types of metal used were mostly Cr-Co non-precious metal alloy and the cases using color coding on the drawing paper of work authorization were not observed. 9. The cases taking secondary impression in the distal extension removable partial denture were 45.71%, 52.46% respectively in the maxillary and mandibular master cast. 10. The delineation of tripoding or reference line on the master cast was not observed in surveying procedure.


MeSH Terms

Alloys
Clinical Coding
Crowns
Denture, Partial, Removable
Laboratories, Dental
Splints
Alloys
Full Text Links
  • KLB
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr