PURPOSE: This study was a randomized single-blind trial of whole versus split-dose PEG solutions for colonoscopy preparation to compare the patient compliance, quality of bowel cleansing, and endoscopist's satisfaction.
METHODS
The participants were recruited from outpatients who planned to receive colonoscopy of C hospital in Busan. Sixty participants were randomly assigned to receive either a spit-dose group(n=30) consuming 2 liter of PEG solution twice, or a whole-dose group(n=30), consuming 4 liter of PEG solution once. These participants completed the questionnaire to assess their compliance before colonoscopy. The quality of bowel cleansing was assessed using the Ottawa Scale with the endoscopist who was blinded to the type of preparation, and their satisfaction by using VAS.
RESULTS
The participants who did not completely consume 4 liter of PEG solution were less in split-dose than in whole-dose group (0% vs 13.3%). The split-dose group complained less about abdominal pain(t=2.644, p=0.009) and abdominal bloating(t=2.802, p=0.013) with a statistical significance. For the quality of bowel preparation, there were no significant differences in the bowel cleansing scores and the endoscopist's satisfaction between two groups.
CONCLUSION