Korean J Thorac Cardiovasc Surg.  2003 Aug;36(8):602-605.

Norwood Procedure with Home-made Bovine Pericardial Patch: A report of 2 cases

Affiliations
  • 1Department of Thoracic & Cardiovascular Surgery, Chosun University College of Medicine, Gwangju, Korea.
  • 2Department of Thoracic & Cardiovascular Surgery, Puchon Sejong General Hospital, Korea. woonghan@korea.com

Abstract

A patch design using bovine pericardial patch for aortic enlargement in the Norwood procedure has been introduced to avoid problems related to homograft availability. We report 2 successful cases of Norwood procedure with home-made bovine pericardial patch. The first case was a 23-day-old (2.2 kg) patient with multi-level left ventricular outflow tract obstruction with ductal-dependent systemic circulation. The other case was a 9-day-old (3 kg) patient with hypoplastic left heart syndrome. This technique was relatively easy to perform, reproducible and quite effective like homograft patch.

Keyword

Norwood procedure; Bovine pericardium