Korean J Spine.  2009 Sep;6(3):228-230.

Delayed Spinal Cord Injury Following Low Voltage Electrical Accident

Affiliations
  • 1Department of Neurosurgery, Bundang Jesaeng General Hospital, Sungnam City, Gyeonggi Province, Korea. shoh1@dmc.or.kr

Abstract

Although the prediction of a delayed spinal cord injury after a low voltage electrical accident is difficult, we present a young paraplegic man who had delayed spinal cord injury after a low voltage electrical accident while working. Because the passage of an electric current is variable, the tissues far distant from the point of entry may be damaged, including the spinal cord. Low voltage itself is not a safe.

Keyword

Delayed spinal cord injury; Low voltage electrical injury; Paraplegia

MeSH Terms

Paraplegia
Spinal Cord
Spinal Cord Injuries
Full Text Links