Korean J Anesthesiol.  1985 Mar;18(1):107-112.

Autommune Hemolytic Anemia Associated with Extracorporeal Circulation

Affiliations
  • 1Department of Anesthesiology, Korea University, College of Medicine Guro Hospital, Seoul, Korea.

Abstract

We noted hemoglobinuris during and after extracorporeal circulation for one case of mitral valve replacement. Laboratory results revealed autoimmune hemolytic anemia(AIHA) including a positive direct Coombs test. A patient with AIHA is serologically incompatible with his own red cells and with the red cells of most blood donors. Red cell transfusion is essential for the management of life threatenting anemia especially in this case. So it is essential, therefore, to have efficient clinician blood bank communication in order to arrive at a rational transfusion therapy for these patients.


MeSH Terms

Anemia
Anemia, Hemolytic*
Blood Banks
Blood Donors
Coombs Test
Extracorporeal Circulation*
Humans
Mitral Valve