Korean Circ J.  1995 Jun;25(3):560-567. 10.4070/kcj.1995.25.3.560.

Diagnostic Value of QT and JT Dispersion in Exercise ECG

Abstract

BACKGROUND
QT dispersion(QTD : QTmax-QTmin) or JT dispersion(JTD:JTmax-JT-min)in 12 leads ECG has been known to reflect regional variations in ventricular repolarization and has been reported to bel one of the marker of regional myocardial ischemia. To evaluate the significance of QTD or JTD of exercise ECG in diagnosis of coronary artery disease, we studied 106 patients(mean age, 56.9 years old, male 63) who were referred for the evaluation of chest pain on exertion. METHOD: Treadmill exercise stress test with modified Bruce protocol and coronary angiography were performed in 106 patients with chest pain on exertion. ST-segment depression by >1.0 mm 0.08 second after J-point during or after exercise in exercise test and >50% stanosis of epicardial artery in coronary angiogram were defined as positive. Of 106 patients, 41 had positive exercise ECG and positive coronary angiogram(true positive, TP), 20 had positive exercise ECG and negative coronary angiogram(false positive, FT), 20 had negative exercise ECG and positive coronary angiogram(faalse negative, FN), and 23 had negative exercise ECG and negative coronary angiogram(true negative, Tn). QT and JT interval in 12 leads were measured at baseline and peakexercise and were corrected for heart rate using Bazett's formula. QTD and JTD were measured by calculation the difference between the maximum QT and mininum QT and that between maximum JT and minumum JT.
RESULTS
QTD at baseline for TP(72.8ms)was prolonged compared to Tn(52.2ms,P<0.01), but was not different from that for FT(70.2 ms). At peak exercise, QTD for TP(81.3 msec) was significantly prolonged(p<0.01), while QTD for FP(71.2 msec) was not different from that for TN(56.8 msec). JTD at baseline(78.4 msec) and at peak exercise(88.2 msec) for TP were significantly prolonged compared to those for TN(55.2msec and 55.1msec p<0.01,p<0.01, respectively), but those for FP were not porlonged(77.0msec and 79.0msec, respectively). QTD and JTD at peak exercise were more markedly prolonged in patients with sever stenosis of coronary artery(p=0.053 and p<0.05, repectively) and multivessels diseases(p<0.01, 0<0.05) than those with less severe disease and single vessel disease. Patients with left anterior descending artery lesion had greater QTD and JTD at peak exercise than those with other vessels lesion(p<0.01). In addition to standard criteria with ST segment displacement in exercise EGC, inclusion of exercise induced QTD of more than 60msec increased the sensitivity of exercise ECG from 66.7% to 83.3%, and JTD of more than 70msec increased the specificity from 52% to 76.0%.
CONCLUSION
Measurement of QT dispersion and JT dispersion of exercise ECG may be useful method to identify the severity of coronary artery disease and to improve diagnostic accuracy of exercise ECG in coronary artery disease.

Keyword

Exercise electrocardiogram; QT dispersion; JT dispersion; Coronary artery disease

MeSH Terms

Arteries
Chest Pain
Constriction, Pathologic
Coronary Angiography
Coronary Artery Disease
Depression
Diagnosis
Electrocardiography*
Exercise Test
Heart Rate
Humans
Male
Myocardial Ischemia
Sensitivity and Specificity
Full Text Links
  • KCJ
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr