J Korean Ophthalmol Soc.  2009 Apr;50(4):529-536. 10.3341/jkos.2009.50.4.529.

Clinical Outcome of Diffractive Multifocal Aspheric Intraocular Lens

Affiliations
  • 1Department of Ophthalmology, Korea University College of Medicine, Seoul, Korea. hyomkim@kumc.or.kr

Abstract

PURPOSE: To compare the clinical outcome between Tecnis ZM900 and Tecnis ZA9003.
METHODS
We reviewed 20 eyes of 11 patients implanted with Tecnis ZM900 and 20 eyes of 20 patients implanted with Tecnis ZA9003. The clinical outcomes of these two intraocular lenses were evaluated one month after operation and consisted of distant, intermediate, and near visual acuity; depth of focus; contrast sensitivity; wavefront aberration; and patient satisfaction. Six months after the operation a reevaluation was performed for the group who had received the Tecnis ZM 900 implant.
RESULTS
Near and intermediate vision was better in the Tecnis ZM900 group. There were no statistical differences between the two groups with respect to distant vision and wavefront aberration. Contrast sensitivity was better in the Tecnis ZA9003 group and depth of focus was deeper in the Tecnis ZM900 group. There were no statically significant differences in the result between one month and six month after the operation.
CONCLUSIONS
The Tecnis multifocal ZM900 IOL can be effective at improving patient satisfaction after cataract surgery as well as for correcting presbyopia.

Keyword

Contrast sensitivity; Depth of focus; Multifocal; Visual acuity; Wavefront aberration

MeSH Terms

Cataract
Contrast Sensitivity
Eye
Humans
Lenses, Intraocular
Patient Satisfaction
Presbyopia
Vision, Ocular
Visual Acuity

Figure

  • Figure 1. The design of Tecnis ZM900 aspheric multifocal intraocular lens.


Cited by  3 articles

Clinical Results and Optical Quality of Diffractive Multifocal IOL Implantation after Myopic Refractive Surgery
Jae Hong Park, Dong Seob Ahn, Sang Jeong Moon, Dong Jun Lee, Sang Youp Han, Kyung Heon Lee
J Korean Ophthalmol Soc. 2014;55(12):1779-1786.    doi: 10.3341/jkos.2014.55.12.1779.

Clinical Results and Optical Quality of Diffractive Multifocal Intraocular Lens
Jeong Jae Oh, Jin Seok Choi
J Korean Ophthalmol Soc. 2015;56(12):1867-1873.    doi: 10.3341/jkos.2015.56.12.1867.

One-year Outcome of Monocular Implant of Aspheric Multifocal IOL
Mi Hyun Cheon, Joo Eun Lee, Jae Hyung Kim, Kyung Hoon Kim, Hee Gyung Lee, Jae Yong Kim, Myoung Joon Kim, Hung Won Tchah
J Korean Ophthalmol Soc. 2010;51(6):822-828.    doi: 10.3341/jkos.2010.51.6.822.


Reference

References

1. Martínez Palmer A, Gómez Faiña P, España Albelda A, et al. Visual function with bilateral implantation of monofocal and multifocal intraocular lenses. J Refract Surg. 2008; 24:257–64.
2. Goes FJ. Refractive lens exchange with the diffractive multifocal tecnis ZM900 intraocular lens. J Refract Surg. 2008; 24:243–50.
Article
3. Fernández-Vega L, Alfonso JF, Rodríguez PP, Montés-Micó R. Clear lens extraction with multifocal apodized intraocular lens implantation. Ophthalmology. 2007; 114:1491–8.
4. Fernández-Vega L, Alfonso JF, Montés-Micó R, Amhaz H. Visual acuity tolerance to residual refractive errors in patients with an apodized diffractive intraocular lens. J Cataract Refract Surg. 2008; 34:199–204.
Article
5. Lee DY, Roh JH, Shyn KH. Current trends in cataract surgery in Korea – 2005 survey for KSCRS members. J Korean Ophthalmol Soc. 2007; 48:485–92.
6. Lane SS, Morris M, Nordan L, et al. Multifocal intraocular lenses. Ophthalmol Clin North Am. 2006; 19:89–105.
7. Hütz WW, Eckhardt HB, Röhrig B, Grolmus R. Reading ability with 3 multifocal intraocular lens models. J Cataract Refract Surg. 2006; 32:2015–21.
Article
8. Kohnen T, Allen D, Boureau C, et al. European multicenter study of the AcrySof ReSTOR apodized diffractive intraocular lens. Ophthalmology. 2006; 113:584.
Article
9. Blaylock JF, Si Z, Vickers C. Visual and refractive status at different focal distances after implantation of the ReSTOR multifocal intraocular lens. J Cataract Refract Surg. 2006; 32:1464–73.
Article
10. Chiam PJ, Chan JH, Aggarwal RK, Kasaby S. ReSTOR intraocular lens implantation in cataract surgery: quality of vision. J Cataract Refract Surg. 2006; 32:1459–63.
Article
11. Sallet G. Refractive outcome after bilateral implantation of an apodized diffractive intraocular lens. Bull Soc Belge Ophtalmol. 2006; 299:67–73.
12. Souza CE, Muccioli C, Soriano ES, et al. Visual performance of AcrySof ReSTOR apodized diffractive IOL: a prospective comparative trial. Am J Ophthalmol. 2006; 141:827–32.
Article
13. Bi H, Cui Y, Ma X, et al. Early clinical evaluation of Acrysof ReSTOR multifical intraocular lens for treatment of cataract. Ophthalmologica. 2008; 222:11–6.
14. Pepose JS, Qazi MA, Davies J, et al. Visual performance of patients with bilateral vs combination Crystalens, Rezoom, and ReSTOR intraocular lense implants. Am J Ophthalmol. 2007; 144:347–57.
15. Vingolo EM, Grenga P, Iacobelli L, Grenga R. Visual acuity and contrast sensitivity: acrysof ReSTOR apodized diffractive vursus Acrysof SA60AT monofocal intraocular lenses. J Cataract Refract Surg. 2007; 33:1244–7.
16. Toto L, Falconio G, Vecchiarino L, et al. Visual performance and biocompatibility of 2 multifocal diffractive IOLs. J Catarct Refract Surg. 2007; 33:1419–25.
Article
Full Text Links
  • JKOS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr