Quantitative Analysis of Magnetization Transfer by Phase Sensitive Method in Knee Disorder

Affiliations
  • 1Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, Korea. bychoe@catholic.ac.kr
  • 2Department of Radiology, College of Medicine, The Catholic University of Korea, Holy Family Hospital, Gyeunggi-Do, Korea.
  • 3Department of Acupuncture, CHA Biomedical Center, College of Medicine, Pochon CHA University, Korea.
  • 4ISOL Technology, 203 Neungpyeong-Ri, Opo-Eub, Gwangju-Si, Gyeonggi-Do, Korea.

Abstract

Magnetization Transfer (MT) imaging generates contrast dependent on the phenomenon of magnetization exchange between free water proton and restricted proton in macromolecules. In biological materials in knee, MT or cross-relaxation is commonly modeled using two spin pools identified by their different T2 relaxation times. Two models for cross-relaxation emphasize the role of proton chemical exchange between protons of water and exchangeable protons on macromolecules, as well as through dipole-dipole interaction between the water and macromolecule protons. The most essential tool in medical image manipulation is the ability to adjust the contrast and intensity. Thus, it is desirable to adjust the contrast and intensity of an image interactively in the real time. The proton density (PD) and T2-weighted SE MR images allow the depiction of knee structures and can demonstrate defects and gross morphologic changes. The PD- and T2-weighted images also show the cartilage internal pathology due to the more intermediate signal of the knee joint in these sequences. Suppression of fat extends the dynamic range of tissue contrast, removes chemical shift artifacts, and decreases motion-related ghost artifacts. Like fat saturation, phase sensitive methods are also based on the difference in precession frequencies of water and fat. In this study, phase sensitive methods look at the phase difference that is accumulated in time as a result of Larmor frequency differences rather than using this difference directly. Although how MT work was given with clinical evidence that leads to quantitative model for MT in tissues, the mathematical formalism used to describe the MT effect applies to explaining to evaluate knee disorder, such as anterior cruciate ligament (ACL) tear and meniscal tear. Calculation of the effect of the effect of the MT saturation is given in the magnetization transfer ratio (MTR) which is a quantitative measure of the relative decrease in signal intensity due to the MT pulse.

Keyword

Magnetization transfer (MT); fat saturation; phase sensitive method; ACL tear; meniscal tear; magnetization transfer ratio (MTR)

MeSH Terms

Anterior Cruciate Ligament
Artifacts
Cartilage
Knee Joint
Knee*
Pathology
Protons
Relaxation
Water
Protons
Water
Full Text Links
  • JKSMRM
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr