J Korean Acad Periodontol.  2000 Jun;30(2):429-441. 10.5051/jkape.2000.30.2.429.

The Effect of a Piezoelectric Ultrasonic Scaler with Curette Tip on Root Substitute Removal in Vitro

Affiliations
  • 1University of Ulsan College of Medicine Asan Medical Center, Korea.

Abstract

Based on current evidence in the literature, it is known that endotoxin is a weakly adherent surface phenomenon and that power-driven instruments can be used to accomplish definitive root detoxification and maximal wound healing without overinstrumentation of root and without extensive cementum removal. And one of the newly developed curette tips used with low power of piezoelectric ultrasonic scaler, is effective to remove calculus and not to remove the excessive cementum. The purpose of this study is therefore, to assess the influence of ultrasonic power and various working parameters on root substitute removal when instrumentation is performed with the curette tip on piezoelectric ultrasonic scaler. This study assessed defect depth, width and area resulting from instrumentation using a piezoelectric ultrasonic scaler with a curette type tip in vitro to acrylic resin block as a root substitute. The working parameters was standardized by the sledge device which controls lateral force(0.5 N, 1 N, 2 N) and instrumentation time(5 sec, 10 sec, 20 sec) and power setting was adjusted 0,2,4,8 in P mode. Power setting had the greatest influence on defect depth compared to lateral force and instrumentation time(standardized regression parameter estimates+/-standard error, 0.37+/-0.02, 0.19+/-0.02, 0.07+/-0.02). The effects on defect area also greatest for power setting(0.57+/-0.03) compared to lateral force and instrumentation time(0.33+/-0.03, 0.12+/-0.03). The effect of the power setting on the defect width(0.15+/-0.01) is not so great as defect depth or defect area compared to lateral force(0.12+/-0.01) and effect of instrumentation time is minimal(0.02+/-0.01). It could be concluded that the power setting has the greatest influence on the defect depth and area in curette type tip with low power of piezoelectric ultrasonic device. Many parameters can be adjusted in various situation in clinical use of piezoelectric ultrasonic scaler but the power setting is the first parameter to be adjusted.

Keyword

dental instrument; periodontal disease; ultrasonic scaler; root substitute; ultrasonic power

MeSH Terms

Calculi
Dental Cementum
Dental Instruments
Periodontal Diseases
Ultrasonics*
Wound Healing

Cited by  2 articles

The effect of working parameters on removal of casting gold alloy using a piezoelectric ultrasonic scaler with scaler tip in vitro
Kuk-Bong Cha, Won-Kyung Kim, Young-Kyoo Lee, Young-Sung Kim
J Korean Acad Periodontol. 2009;39(2):139-148.    doi: 10.5051/jkape.2009.39.2.139.

A morphologic evaluation of defects created by a piezoelectric ultrasonic scaler on casting gold alloy
Young-Sung Kim, Soo-Hwan Kim, Won-Kyung Kim, Young-Kyoo Lee
J Korean Acad Periodontol. 2009;39(4):385-390.    doi: 10.5051/jkape.2009.39.4.385.