J Korean Acad Conserv Dent.  2009 Jul;34(4):333-339. 10.5395/JKACD.2009.34.4.333.

Microleakage of the experimental composite resin with three component photoinitiator systems

Affiliations
  • 1Department of Conservative Dentistry, College of Dentistry, Dankook University, Korea. donyshin@dankook.ac.kr

Abstract

This study was done to determine if there is any difference in microleakage between experimental composite resins, in which various proportions of three component photoinitiators (Camphoroquinone, OPPI, Amine) were included. Four kinds of experimental composite resin were made by mixing 3.2% silanated barium glass (78 wt.%, average size; 1 microm) with each monomer system including variously proportioned photoinitiator systems used for photoinitiating BisGMA/BisEMA/TEGDMA monomer blend (37.5:37.5:25 wt.%). The weight percentage of each component were as follows (in sequence Camphoroquinone, OPPI, Amine): Group A - 0.5%, 0%, 1% / Group B - 2%, 0.2%, 2% / Group C - 0.2%, 1%, 0.2% / Group D - 1%, 1%, 2%. Each composite resin was used as a filling material for round class V cavities (diameter: 2/3 of mesiodistal width; depth: 1.5 mm) made on extracted human premolars and they were polymerized using curing light unit (XL 2500, 3M ESPE) for 40 s with an intensity of 600 mW/cm2. Teeth were thermocycled five-hundred times between 50degrees C and 550degrees C for 30s at each temperature. Electrical conductivity (microA) was recorded two times (just after thermocycling and after three-month storage in saline solution) by electrochemical method. Microleakage scores of each group according to evaluation time were as follows [Group: at first record / at second record; unit (microA)]: A: 3.80 (0.69) / 13.22 (4.48), B: 3.42 (1.33) / 18.84 (5.53), C: 4.18 (2.55) / 28.08 (7.75), D: 4.12 (1.86) / 7.41 (3.41). Just after thermocycling, there was no difference in microleakage between groups, however, group C showed the largest score after three-month storage. Although there seems to be no difference in microleakage between groups just after thermocycling, composite resin with highly concentrated initiation system or classical design (Camphoroquinone and Amine system) would be more desirable for minimizing microleakage after three-month storage.

Keyword

Microleakage; Composite resin; Photoinitiation; Electrical conductivity; Thermocycling

MeSH Terms

Barium
Barium Compounds
Bicuspid
Composite Resins
Electric Conductivity
Glass
Humans
Light
Polymers
Silicon Dioxide
Terpenes
Tooth
Barium
Barium Compounds
Composite Resins
Polymers
Silicon Dioxide
Terpenes

Cited by  1 articles

Optimal combination of 3-component photoinitiation system to increase the degree of conversion of resin monomers
Chang-Gyu Kim, Ho-Jin Moon, Dong-Hoon Shin
J Korean Acad Conserv Dent. 2011;36(4):313-323.    doi: 10.5395/JKACD.2011.36.4.313.


Reference

1. Stansbury JW. Curing dental resins and composites by photopolymerization. J Esthet Dent. 2000. 12:300–308.
Article
2. Ferracane JL, Greener EH. The effect of resin formulation on the degree of conversion and mechanical properties of dental restorative resins. J Biomed Mater Res. 1986. 20(1):121–131.
Article
3. Ferracane JL, Mitchem JC, Condon JR, Todd R. Wear and marginal breakdown of composites with various degrees of cure. J Dent Res. 1997. 76:1508–1516.
Article
4. Wataha JC, Hanks CT, Strawn SE, Fat JC. Cytotoxicity of components of resins and other dental restorative materials. J Oral Rehabil. 1994. 21:453–462.
Article
5. Imazato S, Tarumi H, Kobayashi K, Hiraguri H, Oda K, Tsuchitani Y. Relationship between the degree of conversion and internal discoloration of light-activated composite. Dent Mater J. 1995. 14:23–30.
Article
6. Rueggeberg FA, Ergle JW, Lockwood PE. Effect of photinitiator level on properties of a light-cured and post-cured heated model resin system. Dent Mater. 1997. 13:360–364.
Article
7. Peutzfeldt A, Asmussen E. Influence of ketones on selected mechanical properties. J Dent Res. 1992. 71:1847–1850.
Article
8. Peutzfeldt A, Asmussen E. In vitro wear, hardness, and conversion of diacetyl-containing resin materials. Dent Mater. 1996. 12:103–108.
Article
9. Rietschel RL. Contact allergens in ultraviolet-cured acrylic resin systems. Occup Med. 1986. 1:301–306.
10. Cohen SG, Chao HM. Photoreduction of aromatic ketones by amine. Studies of quantum yields and mechanism. J Am Chem Soc. 1968. 90:165–173.
Article
11. Antonucci JM, Venz S. Tertiary amine salts and complexes as chemical and photochemical accelerators. J Dent Res. 1987. 66:128–Abstr. No. 170.
12. Puppala R, Hegde A, Munshi AK. Laser and light cured composite resin restoration : in-vitro comparison of isotope and dye penetration. J Clin Pediatric Dent. 1996. 20:213–218.
13. Park YJ, Chae KH, Rawls HR. Development of a new photoinitiation system for dental light-cure composite resin. Dent Mater. 1999. 15:120–127.
Article
14. Inano H, Ohba H, Tamaoki B. Photochemical inactivation of human placental estradiol 17 beta-hydrogenase in the presence of 2,3-butandion. J Steroid Biochem. 1983. 19:1617–1622.
15. Eick JD, Kostoryz EL, Rozzi SM, Jacobs DW, Oxman JD, Chappelow CC, Glaros AG, Yourtee DM. In vitro biocompatibility of oxirane/polyol dental composites with promising physical properties. Dent Mater. 2002. 18:413–421.
Article
16. Labella R, Lambrechts P, Van Meerbeek B, Vanherle G. Polymerization shrinkage and elasticity of flowable composites and filled adhesives. Dent Mater. 1999. 15:128–137.
Article
17. Davidson CL, Feilzer AJ. Polymerization shrinkage and polymerization shrinkage stress in polymer-based restoratives. J Dent. 1997. 25:435–440.
Article
18. Braga RR, Ferracane JL. Contraction stress related to degree of conversion and reaction kinetics. J Dent Res. 2002. 81(2):114–118.
Article
19. Ferracane JL, Mitchem JC. Relationship between composite contraction stress and leakage in Class V cavities. Am J Dent. 2003. 16(4):239–243.
20. Gale MS, Darvell BW, Cheung GS. Three-dimensional reconstruction of microleakage pattern using a sequential grinding technique. J Dent. 1994. 22(6):370–375.
Article
21. Crim GA, Chapman KW. Reducing microleakage in Class V restorations: an in vitro study. Quint Int. 1994. 25(11):781–785.
22. Shin DH, Rawls HR. Degree of conversion and color stability of the light curing resin with new photoinitiator systems. Dent Mater. 2009. (in press).
Article
23. Koo BJ, Shin DH. The effect of c-factor and volume on microleakage of composite resin restorations with enamel margins. J Korean Acad Conserv Dent. 2006. 31(6):452–459.
Article
24. Brannstrom M. Communication between the oral cavity and the dental pulp associated with restorative treatment. Oper Dent. 1984. 9:57–68.
25. Tantbirojn D, Versluis A, Pintado MR, DeLong R, Douglas WH. Tooth deformation patterns in molars after composite restoration. Dent Mater. 2004. 20:535–542.
Article
26. Park JW. Comparison of the residual stress of the nanofilled composites. J Korean Acad Conserv Dent. 2008. 33(5):457–462.
Article
27. Gladys S, Meerbeer VB, Lambrechts P, Vanherle G. Microleakage of adhesive restorative materials. Am J Dent. 2001. 14(3):170–176.
28. Hannig M, Friedrichs C. Comparative in vivo and in vitro investigation of interfacial bond variability. Oper Dent. 2001. 26(1):3–11.
29. Jacobsen PH, Von Fraunhofer JA. Assessment of microleakage using a conductimetric technique. J Dent Res. 1976. 54(1):41–48.
Article
30. Delivanis PD, Chapman KA. Comparison and reliability of techniques for measuring leakage and marginal penetration. Oral Surg Oral Med Oral Pathol. 1982. 53:410–416.
Article
31. Kim CY, Shin DH. Microleakage of composite resin restoration according to the number of thermocycling. J Korean Acad Conserv Dent. 2007. 32(4):377–384.
Article
32. Mattison GD, Von Fraunhofer JA. Electrochemical microleakage study of endodontic sealer/cements. Oral Surg Oral Med Oral Pathol. 1983. 55:402–407.
Article
33. Iwami Y, Yamamoto H, Ebisu S. A new electrical method for detecting marginal leakage of in vitro resin restorations. J Dent. 2000. 28:241–247.
Article
34. Nakano Y. A new electrical testing method on marginal leakage of composite resin restorations. Jpn J Cons Dent. 1985. 8:1183–1198.
35. Frankenberger R, Strobel WO, Lohbauer U, Kramer N, Petschelt A. The effect of six years of water storage on resin composite bonding to human dentin. J Biomed Mater Res B Appl Biomater. 2004. 69:25–32.
Article
36. Ferracane JL. Elution of leachable components from composites. J Oral Rehabil. 1994. 21:441–452.
Article
Full Text Links
  • JKACD
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr