J Cerebrovasc Endovasc Neurosurg.  2015 Dec;17(4):295-300. 10.7461/jcen.2015.17.4.295.

Practical Feasibility and Packing Density of Endovascular Coiling Using Target(R) Nano(TM) Coils in Small Cerebral Aneurysms

Affiliations
  • 1Department of Diagnostic Radiology, Busan Paik Hospital, Inje University, Busan, Korea.
  • 2Department of Neurosurgery, Inje University Haeundae Paik Hospital, Busan, Korea. kusmal@hanmail.net

Abstract


OBJECTIVE
Based on the use of Nano(TM) coils, we retrospectively compared the proportion of the coils (< or = 1.5 mm) and packing density in two patient groups with small cerebral aneurysms (< 4 mm diameter) who were treated with or without Nano(TM) coils.
MATERIALS AND METHODS
Between January 2012 and November 2013, in 548 cerebral aneurysms treated by endovascular coiling, 143 patients with 148 small cerebral aneurysms underwent endovascular coiling. After March 2013, coiling with Nano(TM) coils was performed on 45 small cerebral aneurysms (30.4%).
RESULTS
There were no significant differences in the size and locations of the cerebral aneurysms, the age of the patients, and the procedural modalities between the two groups. The proportion of the coil (< or = 1.5 mm) of the group treated with Nano(TM) coils (53.6%) was higher than the proportion of the coil (< or = 1.5 mm) of the group treated without Nano(TM) coils (14.7%) with statistical significance (p < 0.001). The packing density of the group treated with Nano(TM) coils (31.3 +/- 9.69%) was higher than the packing density of the group treated without Nano(TM) coils (29.49 +/- 7.84%), although the difference was not significant. Procedural complications developed in 3 lesions (2 thromboembolisms and 1 carotid dissection) (2.0%). Treatment-related transient neurological deficits due to thromboembolism developed in 1 lesion, which had not been treated with Nano(TM) coils. There was no treatment-related permanent morbidity or mortality in either of the groups.
CONCLUSION
In our series, the small cerebral aneurysms treated with Nano(TM) coils showed more packing density with no additive procedural risk or difficulty.

Keyword

Cerebral aneurysm; Endovascular

MeSH Terms

Humans
Intracranial Aneurysm*
Mortality
Retrospective Studies
Thromboembolism

Cited by  1 articles

Recurrence of Small Cerebral Aneurysms (< 4 mm) Treated Endovascularly Using Target® Nano™ Coils
Sung Min Kim, Hyun Gon Lee, Byung Sam Choi, Jung Soo Kim, Sung Joon Lee, Hae Yu Kim, Sung Tae Kim, Young Gyun Jeong, Jin Wook Baek, Hae Woong Jeong, Sung-Chul Jin
J Cerebrovasc Endovasc Neurosurg. 2018;20(2):106-111.    doi: 10.7461/jcen.2018.20.2.106.


Reference

1. Moret J, Cognard C, Weill A, Castaings L, Rey A. The remodelling technique in the treatment of wide neck intracranial aneurysms. Angiographic results and clinical follow-up in 56 cases. Interv Neuroradiol. 1997; 3. 3(1):21–35. PMID: 20678369.
2. Wakhloo AK, Gounis MJ, Sandhu JS, Akkawi N, Schenck AE, Linfante I. Complex-shaped platinum coils for brain aneurysms: higher packing density, improved biomechanical stability, and midterm angiographic outcome. AJNR Am J Neuroradiol. 2007; 8. 28(7):1395–1400. PMID: 17698550.
Article
3. Gaba RC, Ansari SA, Roy SS, Marden FA, Viana MA, Malisch TW. Embolization of intracranial aneurysms with hydrogel-coated coils versus inert platinum coils: effects on packing density, coil length and quantity, procedure performance, cost, length of hospital stay, and durability of therapy. Stroke. 2006; 6. 37(6):1443–1450. PMID: 16675742.
4. Kwon OK, Kim SH, Oh CW, Han MH, Kang HS, Kwon BJ, et al. Embolization of wide-necked aneurysms with using three or more microcatheters. Acta Neurochir (Wien). 006; 11. 148(11):1139–1145. discussion 1145PMID: 16990989.
Article
5. Kwon OK, Kim SH, Kwon BJ, Kang HS, Kim JH, Oh CW, et al. Endovascular treatment of wide-necked aneurysms by using two microcatheters: techniques and outcomes in 25 patients. AJNR Am J Neuroradiol. 2005; 4. 26(4):894–900. PMID: 15814940.
6. Roy D, Milot G, Raymond J. Endovascular treatment of unruptured aneurysms. Stroke. 2001; 9. 32(9):1998–2004. PMID: 11546888.
Article
7. Babiker MH, Gonzalez LF, Albuquerque F, Collins D, Elvikis A, Frakes DH. Quantitative effects of coil packing density on cerebral aneurysm fluid dynamics: an in vitro steady flow study. Ann Biomed Eng. 2010; 7. 38(7):2293–2301. PMID: 20306135.
Article
8. Morales HG, Kim M, Vivas EE, Villa-Uriol MC, Larrabide I, Sola T, et al. How do coil configuration and packing density influence intra-aneurysmal hemodynamics? AJNR Am J Neuroradiol. 2011; Nov-Dec. 32(10):1935–1941. PMID: 21885712.
Article
9. Chalouhi N, Dumont AS, Hasan D, Tjoumakaris S, Gonzalez LF, Starke RM, et al. Is packing density important in stent-assisted coiling? Neurosurgery. 2012; 8. 71(2):381–386. discussion 386-7PMID: 22569059.
Article
10. Ioannidis I, Lalloo S, Corkill R, Kuker W, Byrne JV. Endovascular treatment of very small intracranial aneurysms. J Neurosurg. 2010; 3. 112(3):551–556. PMID: 19715422.
Article
11. Brinjikji W, Lanzino G, Cloft HJ, Rabinstein A, Kallmes DF. Endovascular treatment of very small (3 mm or smaller) intracranial aneurysms: report of a consecutive series and a meta-analysis. Stroke. 2010; 1. 41(1):116–121. PMID: 19926837.
Full Text Links
  • JCEN
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr