Hip Pelvis.  2015 Dec;27(4):216-222. 10.5371/hp.2015.27.4.216.

Total Hip Arthroplasty Using Metal Head on a Highly Cross-linked Polyethylene Liner

Affiliations
  • 1Department of Orthopaedic Surgery, Kwangju Christian Hospital, Gwangju, Korea. Paedic@chol.com

Abstract

PURPOSE
This retrospective study was performed to evaluate the clinical results and measure polyethylene liner wear in total hip arthroplasty (THA) with highly cross-linked polyethylene.
MATERIALS AND METHODS
Except for patients who had died or were unable to have follow-up at least 2 years, 60 of 78 hips that underwent THA were included this study. The mean age was 64.5 years (range, 25-81 years) and the mean body mass index (BMI) was 23.0 kg/m2 (18.1-32.3 kg/m2). Diagnosis at the time of the operation was osteonecrois of the femoral head in 28 hips, primary osteoarthritis in 14, hip fracture in 13, and other diseases in 5. The mean follow-up period was 3.8 years (2.1-7.1 years). Harris hip score (HHS) was reviewed before THA and at the last follow-up. On the anteroposterior pelvic radiographs, acetabular cup inclination and ante-version were also measured. The annual linear wear rate was measured using Livermore's method on the radiographs.
RESULTS
The mean HHS was 60.1 (28-94) before operation and 90.4 (47-100) at the last follow-up. In the immediate post-operation, the average inclination and anteversion angles of the acetabular cups were 46.3degrees (standard deviation, +/-6.7degrees) and, 21.4degrees(+/-10.1degrees) respectively. The mean of the annual linear polyethylene wear was 0.079 mm/year (0.001-0.291 mm/year). Age, gender and BMI were not statistically related to linear polyethylene wear but the period of follow-up and the acetabular cup's inclination showed significant negative and positive correlation respectively.
CONCLUSION
The wear rate of a highly cross-linked polyethylene was shown to correlate negatively with duration of follow-up. However, our study was based on a short-term follow-up, so a long-term follow-up study is necessary in the future.

Keyword

Total hip arthroplasty; Highly cross-linked polyethylene; Linear wear rate

MeSH Terms

Acetabulum
Arthroplasty, Replacement, Hip*
Body Mass Index
Diagnosis
Follow-Up Studies
Head*
Hip
Humans
Osteoarthritis
Polyethylene*
Retrospective Studies
Polyethylene

Figure

  • Fig. 1 A scatter plots show linear correlation the annual wear rate of polyethylene versus the period of follow-up (A) and inclination angles of the acetabular cups (B). The y-axis is the annual wear rate of polyethylene (mm/year), x-axis are the period of follow-up (years) and inclination angles of the acetabular cups (°). The dash lines show the regression lines of linear correlation the annual wear rate of polyethylene versus the period of follow-up and inclination angles of the acetabular cups.

  • Fig. 2 Each divided into groups of the period of follow-up (A) and inclination angles of the acetabular cups (B), a flow plots show the means of annual wear rate of polyethylene and the total wear during follow up. The y-axis is the means of annual wear rate of polyethylene (mm/year), x-axis are different groups by the period of follow-up (years) and inclination angles of the acetabular cups (°). The dash lines represent the regression lines of linear correlation.


Reference

1. Laupacis A, Bourne R, Rorabeck C, et al. The effect of elective total hip replacement on health-related quality of life. J Bone Joint Surg Am. 1993; 75:1619–1626.
Article
2. Malchau H, Herberts P. Prognosis of total hip replacement. Int J Risk Saf Med. 1996; 8:27–45.
Article
3. Clohisy JC, Calvert G, Tull F, McDonald D, Maloney WJ. Reasons for revision hip surgery: a retrospective review. Clin Orthop Relat Res. 2004; (429):188–192.
4. Harris WH. Conquest of a worldwide human disease: particle-induced periprosthetic osteolysis. Clin Orthop Relat Res. 2004; (429):39–42.
5. Bauer TW. Particles and periimplant bone resorption. Clin Orthop Relat Res. 2002; (405):138–143.
Article
6. Böhler M, Kanz F, Schwarz B, et al. Adverse tissue reactions to wear particles from Co-alloy articulations, increased by alumina-blasting particle contamination from cementless Ti-based total hip implants. A report of seven revisions with early failure. J Bone Joint Surg Br. 2002; 84:128–136.
7. van der Weegen W, Sijbesma T, Hoekstra HJ, Brakel K, Pilot P, Nelissen RG. Treatment of pseudotumors after metal-on-metal hip resurfacing based on magnetic resonance imaging, metal ion levels and symptoms. J Arthroplasty. 2014; 29:416–421.
Article
8. Kurtz SM, Gawel HA, Patel JD. History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene. Clin Orthop Relat Res. 2011; 469:2262–2277.
Article
9. Jacobs CA, Christensen CP, Greenwald AS, McKellop H. Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty. J Bone Joint Surg Am. 2007; 89:2779–2786.
Article
10. García-Rey E, García-Cimbrelo E. Polyethylene in total hip arthroplasty: half a century in the limelight. J Orthop Traumatol. 2010; 11:67–72.
Article
11. Onsten I, Carlsson AS, Ohlin A, Nilsson JA. Migration of acetabular components, inserted with and without cement, in one-stage bilateral hip arthroplasty. A controlled, randomized study using roentgenstereophotogrammetric analysis. J Bone Joint Surg Am. 1994; 76:185–194.
Article
12. Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am. 1990; 72:518–528.
Article
13. Schmalzried TP, Kwong LM, Jasty M, et al. The mechanism of loosening of cemented acetabular components in total hip arthroplasty. Analysis of specimens retrieved at autopsy. Clin Orthop Relat Res. 1992; (274):60–78.
14. Maloney WJ, Galante JO, Anderson M, et al. Fixation, polyethylene wear, and pelvic osteolysis in primary total hip replacement. Clin Orthop Relat Res. 1999; (369):157–164.
Article
15. Sochart DH. Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. Clin Orthop Relat Res. 1999; (363):135–150.
Article
16. Oparaugo PC, Clarke IC, Malchau H, Herberts P. Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: a survey of 8 reports in the literature. Acta Orthop Scand. 2001; 72:22–28.
Article
17. McKellop H, Shen FW, Lu B, Campbell P, Salovey R. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res. 1999; 17:157–167.
Article
18. Kang JS, Kim RS. Metal on polyethylene in total hip arthroplasty. J Korean Hip Soc. 2010; 22:241–246.
Article
19. McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB, Chess DG, Charron KD. Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial. J Bone Joint Surg Am. 2009; 91:773–782.
20. Lee JH, Lee BW, Lee BJ, Kim SY. Midterm results of primary total hip arthroplasty using highly cross-linked polyethylene: minimum 7-year follow-up study. J Arthroplasty. 2011; 26:1014–1019.
Article
21. Sychterz CJ, Engh CA Jr, Shah N, Engh CA Sr. Radiographic evaluation of penetration by the femoral head into the polyethylene liner over time. J Bone Joint Surg Am. 1997; 79:1040–1046.
Article
22. Sychterz CJ, Engh CA Jr, Yang A, Engh CA. Analysis of temporal wear patterns of porous-coated acetabular components: distinguishing between true wear and socalled bedding-in. J Bone Joint Surg Am. 1999; 81:821–830.
23. Devane PA, Horne JG, Martin K, Coldham G, Krause B. Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris. J Arthroplasty. 1997; 12:256–266.
24. Young AM, Sychterz CJ, Hopper RH Jr, Engh CA. Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty. J Bone Joint Surg Am. 2002; 84-A:58–63.
Article
25. Manning DW, Chiang PP, Martell JM, Galante JO, Harris WH. In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty. J Arthroplasty. 2005; 20(7):880–886.
Article
26. Hermida JC, Bergula A, Chen P, Colwell CW Jr, D'Lima DD. Comparison of the wear rates of twenty-eight and thirty-two-millimeter femoral heads on cross-linked polyethylene acetabular cups in a wear simulator. J Bone Joint Surg Am. 2003; 85-A:2325–2331.
Article
Full Text Links
  • HP
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr