J Korean Orthop Assoc.
2005 Jun;40(3):365-368.
An Inguinal Mass associated with Polyethylene Wear Debris after a Total Hip Arthroplasty: A Case Report
- Affiliations
-
- 1Department of Orthopaedic Surgery, College of Medicine, Pusan National University, Busan, Korea. kuentak@pusan.ac.kr
Abstract
- Ostelolysis and implant loosening by wear particles after a total hip arthroplasty is a well-documented phenomenon. Howerver, the occurrence of a soft tissue mass around the hip joint after a total hip arthroplasty is rare. We experienced a case of an inguinal mass associated with polyethylene wear particles. An excision of the mass and revision arthroplasty for a polyethylene liner and metal head were performed successfully via a separate incision. We describe this rare case with a review of the relevant literature.