Comparison of Maximal Removal Rate of Indocyanine Green and Monoethylglycinexylidide Test in Quantitative Assessment of Hepatic Function

Abstract

BACKGROUND: The maximal removal rate of indocyanine green (ICG Rmax), which has been used as a useful indicator of quantitative assessment of the hepatic function, has some disadvantages such as high cost, requirement of multiple sampling, and long turn-around time. This study was designed to clarify that the measurement of the lidocaine metabolite, monoethylglycinekylidide (MEGX) test, can replace the ICG Rmax. And in healthy adults, MEGX forma pion was measured and compared according to methods of measurement and serf. METHOD: In 18 patients to whom ICG Rmax test was requested, ICG Rmax test was carried out at two doses of 0.5 mg/kg and 5 mg/kg and MEGX formation after 15 minute of 1 mg/kg lidocaine Injection was measured by fluorescence polarization immunoassay (FPIA) method. The correlation between them was analyzed, To 25 healthy volunteers included in this study as normal control, lidocaine was given intravenously at, a dose of 1 mg/kg and MEGX forma pion was measured IS and 30 minute later (MEGX15, MEGX30) using both high performance liquid chromatography (HPLC) and FPIA methods. RESULT: Patient group resealed significant correlation between ICG Rmax and MEGX15 (r=0.7674, p<0.001) and also between ICG Rl5 and MEGX15 (r=0.5612, p=0.008). There was significant difference between MEGX15 of 9 patients with chronic liver diseases and those of normal controls (22.24+/- 13.18 and 35.40+/- 14.43 ng/mL, respectively) (p=0.01). In normal controls, the correlation between methods was significant (p=0.001) and the values measured by FPIA method was significantly higher than that by HPLG (p(0.001). Of the normal controls, male group had higher MEGX15 values than female group in both methods (in HPLC method 33.89+/-15.95 and 22.53+/- 8.36, and in FPIA method 41.48+/-16.61 and 28.81+/-7.88 ng/mL, respectively), and in female group MEGX30 values was significantly elevated compared to MEGX15 (p<0.001).
CONCLUSION
Inferred from the fact that the correlation between ICG Rmax and MEGX was good, MEGX test can be considered a replacement for ICG Rmax. In healthy adults, it is considered that there is serf-related difference In the rate of lidocaine metabolism so we should pay attention to it in interpreting the MEGX results.


MeSH Terms

Adult
Chromatography, High Pressure Liquid
Chromatography, Liquid
Female
Fluorescence Polarization Immunoassay
Healthy Volunteers
Humans
Indocyanine Green*
Lidocaine
Liver Diseases
Male
Mesons
Metabolism
Indocyanine Green
Lidocaine
Full Text Links
  • KJCP
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr