Tuberc Respir Dis.  1995 Oct;42(5):772-776. 10.4046/trd.1995.42.5.772.

A Case of Removal of Pushpin by Flexible Bronchoscopy

Affiliations
  • 1Department of Internal Medicine, College of Medicine, Inha University, Sungnam, Korea.

Abstract

Aspiration of foreign body, a clinical problem seen more commonly in the pediatric age group, is infrequently seen in the adult population. Although rigid bronchoscopy has been the mainstay of treatment, recently, easier manipulation, greater range of visulization, flexibility, topical anesthesia has made flexible bronchoscopy of choice for dealing with aspirated foreign body in adult. Operation increase morbidity and mortality, delay foreigh body removal. A 41-year old male was admitted to this hospital due to aspiration of pushpin. He showed high opaque density protruding in the orifice of right lower lobar bronchus. We report a case of foreign body removal by flexible bronchoscopy with brief review of the literature.

Keyword

Foreign body; Flexible bronchoscopy

MeSH Terms

Adult
Anesthesia
Bronchi
Bronchoscopy*
Foreign Bodies
Humans
Male
Mortality
Pliability

Cited by  1 articles

A Case of Massive Hemoptysis & Pneumonia Caused by Metallic Foreign Body
Choon Hee Chang, Jang Eun Lee, Hyung wook Park, Jeong hwa Lee, Seung Ah Yang, Young Kun Park, Sang Rok Lee, Jin Young An
Tuberc Respir Dis. 2006;61(6):567-572.    doi: 10.4046/trd.2006.61.06.567.

Full Text Links
  • TRD
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr