STUDY DESIGN: Retrospective study.
OBJECTIVES
To analyze the influence of fracture patterns and the result of bone mineral density on cement leakage after percutaneous vertebroplasty for osteoporotic vertebral compression fractures. SUMMARY OF LITERATURE REVIEW: Leakage of bone cement after vertebroplasty has known to be related with the direction of cortical disruption of fractured vertebral body and low bone mineral density (BMD).
MATERIALS AND METHODS
One hundred eighty-two patients with osteoporotic vertebral compressions were studied from January 2009 to August 2013. The patients' fracture levels and patterns were compared. Among them, the cement leakage patterns were analyzed in 105 patients who had undergone vertebroplasty. The findings were compared with fracture patterns including cortical disruption and BMD.
RESULTS
Seventy-five cases of cement leakage were observed. Among them, intradiscal leakage was the most common type of leakage. In the patient group with low BMD, there was a high incidence of lower and posterior cortical disruption in the fractures. Patients with posterior cortical disruption demonstrated a higher incidence of leakage into the spinal canal and anterior cortex. No significant correlation was observed between fracture patterns and leakage.
CONCLUSIONS
A surgeon should use caution in performing vertebroplasty in patients with low BMD and posterior disruption of the vertebral cortex.

Keyword

Osteoporosis; Compression fracture; Cement leakage; Fracture pattern; Bone mineral density

MeSH Terms

Bone Density*
Fractures, Compression*
Humans
Incidence
Osteoporosis
Retrospective Studies
Spinal Canal
Vertebroplasty*

Reference

1. Galibert P, Deramond H, Rosat P, Le Gars D. Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty. Neurochirurgie. 1987; 33:166–8.
2. Paovani B1, Kasriel O, Brunner P, Pertti-Viton P. Pulmonary embolism caused by acrylic cement: a rare complication of percutaneous vertebroplasty. AJNR Am J Neurora-diol. 1999; 20:375–7.
3. Barr JD, Barr MS, Lemley TJ, Mccann RM. Percutaneous vertebroplasty for pain relief and spinal stablization. Spine (Phila Pa 1976). 2000; 25:923–8.
4. Deramond H, Depreister C, Galibert P, Le Gars D. Percutaneous vertebroplasty with polymethylmethacrylate; technique, indication, and results. Radiologic Clinics of North America. 1998; 36:533–46.
5. Weill A, Chiras J, Simon JM, Rose M, Sola-Martinez T, Enkaoua E. Spinal metastasis: indications for and results of percutaneous injection of acrylic surgical cement. Radiology. 1996; 199:241–7.
6. Lindsay R, Burge RT, Strauss DM. One year outcomes and costs following a vertebral fracture. Osteoporos Int. 2005; 16:78–85.
Article
7. Perez-Higueras A, Alvarez L, Rossi RE, Quinones D, Al- Assir I. Percutaneous vertebroplasty: longterm clinical and radiological outcome. Neroradiology. 2002; 44:950–4.
8. Cotton A, Dewatre F, Cortet B, et al. Percutaneous vertebroplasty for osteolytic metastases and myeloma: effects of the percentage of lesion filling and the leakage of mrthyl methacrylate at clinical followup. Radiology. 1996; 200:525–30.
9. Ratliff J, Nguyen T, Heiss J. Root and spinal cord compression from methylmethacrylate vertebroplasty. Spine (Phila Pa 1976). 2001; 26:300–2.
Article
10. Yoo KY, Jeong SW, Yoon W, Lee J. Acute respiratory dis-tress syndrome associated with pulmonary cement embolism following percutaneous vertebroplasty with polymeth-ylmethacrylate. Spine (Phila Pa 1976). 2004; 29:294–7.
Article
11. Mousavi P, Roth S, Finkelstein J, Cheung G, Whyne C. Volumetric quantification of cement leakage following percutaneous vertebroplasty in metastatic and osteoporotic vertebrae. Neurosurg. 2003; 99:56–9.
Article
12. Shin KS, Kim JS, Lee DW. Surgical treatment of root injury after percutaneous vertebroplasty: case report. J Korean Soc Spine Surg. 2002; 9:54–8.
Article
13. Graham J, Ahn C, Hai N, Buch BD. Effect of bone density on vertebral strength and stiffness after percutaneous vertebroplasty. Spine. 2007; 32(18):E505–11.
Article
14. Teyssedou S, Saget M, Pries P. Kyphopasty and vertebroplasty. Orthopaedics & traumatology, surgery & research: OTSR. 2014; 100(1 Suppl):S169–79.
15. Hong SJ, Lee S, Yoon JS, Kim JH, Park YK. Analysis of intradiscal cement leakage during percutaneous vertebroplasty: multivariate study of risk factors emphasizing pre-operative MR findings. Journal of neuroradiology Journal de neuroradiologie. 2014; 41:195–201.
Article
16. Black DM, Arden NK, Palermo L, Pearson J, Cummings SR. Prevalent vertebral deformities predict hip fractures and new vertebral deformities but not wrist fractures. Study of Osteoporotic Fractures Research Group. Journal of bone and mineral research: the official journal of the American Society for Bone and Mineral Research. 1999; 14:821–8.
17. Corcos G, Dbjay J, Mastier C, et al. Cement leakage in percutaneous vertebroplasty for spinal metastases: a retrospective evaluation of incidence and risk factors. Spine. 2014; 39:E332–8.
Full Text Links
  • JKSS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr