J Korean Soc Ther Radiol.  1987 Dec;5(2):165-168.

Application of Generalized Batho Method to Arbitrary Shape of Heterogeneous Tissues

Affiliations
  • 1Department of Therapeutic Radiology, College of Medicine, Seoul National University, Seoul, Korea.

Abstract

The generalized Batho method, proposed by Webb and Fox, which is a method of calculation of dose correction factor for the multilayer of heterogeneous tissue, is complex even for a few kind of tissues. The method was modified for the purpose of getting a simple method that divide the multilayer of heterogeneous tissues into some groups of adjacent-tissue pairs. This new method could reduce the number of exponential terms and the time for calculating the dose correction factors by manual and computer calculation.