Korean Circ J.  1996 Feb;26(1):29-34. 10.4070/kcj.1996.26.1.29.

Angiographic Follow-up after Intracoronary Stenting with Flexible Coil(Gianturco-Roubin) Stent

Abstract

BACKGROUND
Intracoronary stent with various designs have been developed to treat dissections or acute closure after angioplasty. The efficacy of flexible coil stent as a bail-out device has been reported. However, the restenosis after stenting still remained as a main limitation like other devices. This study reports on the angiographic follow-up after successful intracoronary stenting with flexible coil stent. METHOD: From April 1993 through July 1994, coronary stenting was tried in 21 patients by a single operator for various indications(acute or threatened closure, suboptimal result after balloon angioplasty). The nineteen(95%) out of 20 patients in whom stent was successfully deployed underwent follow-up coronary angiography 7.6+/-3.0 months after coronary stenting. RESULT: Mean age was 54.7+/-11.3(33-73) years and 16 parients were men. Clinical diagnosis of patients were as follows : stable angina 7, unstable angina 6, old myocardial infarction with stable angina 6 and acute myocardial infarction in 1 patient, respectively. Stents were implanted at left anterior descending artery in 9, left circumflex artery in 5 and right coronary artery in 8. Ten out of 21 stents(47.6%) were found to be renarrowed more than 50% at follow-up coronary angiography. There was no significant difference in clinical and angiographic variables between restenosis group and no-restenosis group. Coronary artery bypass graft surgery was performed in 1 patient for the treatment of restenosis after stenting. Repeat PTCA was performed in 3 patients and remaining 5 patients were followed medically.
CONCLUSION
Flexible coil(Gianturco-Roubin) coronary stent is a useful adjunct percutaneous intervention to prevent or minimize complicatioms associated with dissections. Despite favorable initial angiographic and clinical results, 47.6% of stents were found to be renarrowed significantly at follow-up coronary angiography. New techniques or more optimal characters of stents would be desired.

Keyword

Flexible coil(Gianturco-Roubin) coronary stent; Angiographic follow-up

MeSH Terms

Angina, Stable
Angina, Unstable
Angioplasty
Arteries
Coronary Angiography
Coronary Artery Bypass
Coronary Vessels
Diagnosis
Follow-Up Studies*
Humans
Male
Myocardial Infarction
Stents*
Transplants
Full Text Links
  • KCJ
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles