Anesth Pain Med.  2012 Jul;7(3):266-270.

Obstruction of the endotracheal tube due to cyanoacrylate leakage in a pediatric recurrent tracheoesophageal fistula patient: A case report

Affiliations
  • 1Department of Anesthesiology and Pain Medicine, Chungnam National University School of Medicine, Daejeon, Korea. seohwy@cnu.ac.kr

Abstract

A 6-year old female, who was operated on for tracheoesophageal fistula at the time of birth, was diagnosed with recurrent TEF, and it was decided to undergo endoscopic management, using cyanoacrylate under general anesthesia. After cuffing, the endotracheal tube was located at the level of the fistula, and endoscopic management was undertaken through the esophagus, using cyanoacrylate. The peak inspiratory pressure was shown to have increased from 18 to 28 cmH2O. We observed partial obstruction of the endotracheal tube end, and partial attachment of the cyanoacrylate to the tracheal wall. The patient's symptoms gradually improved, and no other particular finding was observed during the following two months. We suppose that the cyanoacrylate has been ventilated, and gradually excreted. In manipulation that may cause changes in the tube position, it is recommended to check ventilation via the fistula, and to recheck the tube position.

Keyword

Cyanoacrylate; Endotracheal tube; Tracheoesophageal fistula

MeSH Terms

Anesthesia, General
Cyanoacrylates
Esophagus
Female
Fistula
Humans
Parturition
Tracheoesophageal Fistula
Ventilation
Cyanoacrylates
Full Text Links
  • APM
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr