J Korean Radiol Soc.  2006 Oct;55(4):361-371. 10.3348/jkrs.2006.55.4.361.

The Usefulness of In Vitro Proton Magnetic Resonance Spectroscopy for Differentiating Between Abdominal Body Fluids

Affiliations
  • 1Department of Diagnostic Radiology, Chonnam National University Hospital, Korea. kjradsss@dreamwiz.com
  • 2Department of Diagnostic Radiology, Chonnam National University Hwasun Hospital, Korea.

Abstract

PURPOSE
The purpose of this study was to determine whether in vitro proton (1H) magnetic resonance spectroscopy (MRS) is useful for distinguishing between abdominal types of fluids.
MATERIALS AND METHODS
Thirty fluid samples that were obtained from patients who were undergoing diagnostic or therapeutic percutaneous drainage of abdominal fluids were examined in this study. According to their gross appearance and smell, each sample was classified as either purulent fluid (n=12) or non-purulent fluid (n=18). The non-purulent fluids were subdivided into hemorrhagic fluid (n=2), serosanguinous fluid with debris (n=2), and serosanguinous fluid without debris (n=14). In addition, according to the cytologic analysis, each sample was classified as either benign fluid (n=23) or malignant fluid (n=7). A set of humoral pathological examinations that included biochemical analysis and culture of the fluid were performed for all the fluid samples. In vitro 1H MRS was performed by using a 1.5T MR system and a birdcage head coil. MR spectra were obtained by using point-resolved spectroscopy (PRESS) (TR/TE=2000/30 msec) with water suppression. The MR spectra were analyzed on the basis of agreement between a radiologist and a physicist who worked in consensus.
RESULTS
The MR spectra obtained from 30 samples could be classified into 8 different patterns, according to the presence of lipid (0.9/1.3 ppm), lactate (1.3 ppm), acetate (1.9 ppm), and succinate (2.4 ppm) peaks. The MR spectral patterns of the purulent fluids (n=12) were classified as follows: pattern-1 (n=7, 58%), pattern-2 (n=2, 17%), pattern-3 (n=1, 8%), pattern-6 (n=1, 8%) and pattern-8 (n=1, 8%). The MR spectral patterns of the non-purulent fluids (n=18) were classified as follows: pattern-4 (n=1, 6%), pattern-5 (n=5, 28%), pattern-6 (n=1, 6%), pattern-7 (n=3, 17%) and pattern-8 (n=8, 44%). The MR spectral patterns of the purulent fluids were significantly different from those of the non-purulent fluids (p < .05). The MR spectral patterns of benign fluids (n=23) were classified as follows: pattern-1 (n=7, 30%), pattern-2 (n=2, 9%), pattern-3 (n=1, 4%), pattern-4 (n=1, 4%), pattern-5 (n=3, 13%), pattern-6 (n=2, 9%), pattern-7 (n=1, 4%) and pattern-8 (n=6, 26%). The MR spectral patterns of malignant fluids (n=7) were classified as follows: pattern-5 (n=2, 29%), pattern-7 (n=2, 29%) and pattern-8 (n=3, 43%). No significant difference was found between the spectral patterns of the benign and malignant fluids (p= .300).
CONCLUSION
In vitro 1H MRS could be useful for differentiating between purulent fluid and non-purulent fluid.

Keyword

Magnetic resonance(MR), spectroscopy; Abscess; Abdomen, abscess

MeSH Terms

Abscess
Body Fluids*
Consensus
Drainage
Head
Humans
Lactic Acid
Magnetic Resonance Spectroscopy*
Protons*
Smell
Spectrum Analysis
Succinic Acid
Water
Lactic Acid
Protons
Succinic Acid
Water
Full Text Links
  • JKRS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr