J Korean Fract Soc.  2005 Oct;18(4):399-404. 10.12671/jkfs.2005.18.4.399.

Conformity of the LCP-DF (Locking Compression Plate-Distal Femur) in Korean Adult Femur: A Cadaver Study

Affiliations
  • 1Department of Orthopedic Surgery, Dongdaemun Hospital, Ewha Womans University, Seoul, Korea. jongkeon@ewha.ac.kr
  • 2Department of Orthopedic Surgery, Kyungpook National University Hospital, 50, 2-Ga, SamDok-Dong, Chung-Gu, Daegu, 700-721, Korea.
  • 3Department of Anatomy, College of Medicine, Korea University, Anam-dong 5ga, Seongbuk-gu, 136-705, Seoul Korea.

Abstract

PURPOSE: To evaluate the conformity of the anatomically pre-shaped LCP-DF to the femurs of the Korean adult.
MATERIALS AND METHODS
67 adult femur obtained from the Korean adult cadaver were used. An eleven-hole LCP-DF was applied to the lateral surface of the distal femur according to the contour. Then the distance from the inner surface of the plate to the cortex was measured at the sites of mismatch. The angle between the distal most screw and the articular surface was measured.
RESULTS
Mismatch was found at the level of proximal 4~5 holes of the plate with an average distance of 9.58 mm (0~18) at the tip of the plate. Otherwise, the overall conformity of the LCP-DF was excellent. The distal most screws are positioned such that the joint line is 3 degrees of valgus to this screw in average (range 0~18).
CONCLUSION
It may be necessary to consider to bend the plate in case of mismatch at the tip especially for the plate longer than 9-hole plate. The angular relation between the distal most screw and the joint line can assist the judgement for the coronal plane alignment.

Keyword

Femur; Anatomically pre-shaped plate; LCP-DF; Conformity

MeSH Terms

Adult*
Cadaver*
Femur*
Humans
Joints

Cited by  6 articles

Pitfalls and Complications in the Application of the Locking Plate
Jong-Keon Oh
J Korean Fract Soc. 2007;20(4):355-360.    doi: 10.12671/jkfs.2007.20.4.355.

Treatment of Distal Femoral Fractures Using Polyaxial Locking Plate
Sang-Eun Park, Hyun-Taek Kang, Young-Yul Kim, Jae-Jung Jeong, Jung-U Lee, Weon-Yoo Kim
J Korean Fract Soc. 2011;24(4):321-327.    doi: 10.12671/jkfs.2011.24.4.321.

Repeated Metal Breakage in a Femoral Shaft Fracture with Lateral Bowing - A Case Report -
Dong Soo Kim, Yong Min Kim, Eui Sung Choi, Hyun Chul Shon, Kyoung Jin Park, Byung Ki Cho, Ji Kang Park, Hyun Cheol Lee, Kyung Ho Hong
J Korean Fract Soc. 2012;25(2):136-141.    doi: 10.12671/jkfs.2012.25.2.136.

Comparison of Results of Minimally Invasive Plate Osteosynthesis according to Types of Locking Plate in Distal Femoral Fractures
Oog Jin Shon, Moon Soo Kwon, Chul Hyun Park
J Korean Fract Soc. 2012;25(4):269-276.    doi: 10.12671/jkfs.2012.25.4.269.

Comparison of Results of Minimally Invasive Plate Osteosynthesis according to Types of Locking Plate in Distal Femoral Fractures
Oog Jin Shon, Moon Soo Kwon, Chul Hyun Park
J Korean Fract Soc. 2012;25(4):269-276.    doi: 10.12671/jkfs.2012.25.4.269.

Axial Malalignment after Minimally Invasive Plate Osteosynthesis in Distal Femur Fractures with Metaphyseal Comminution
Jae-Ho Jang, Gu-Hee Jung, Jae-Do Kim, Cheung-Kue Kim