J Korean Soc Radiol.  2013 Jul;69(1):23-27. 10.3348/jksr.2013.69.1.23.

Evaluation of the Incidence on Insufficient Cytology Results Comparing Different Ultrasound-Guided Aspiration Techniques for Thyroid Nodules

Affiliations
  • 1Department of Radiology, Jeju National University Hospital, Jeju National University School of Medicine, Jeju, Korea. jkcontrast@naver.com

Abstract

PURPOSE
We compared the incidence of insufficient thyroid cytology due to blood-stained materials or low cellularity in terms of aspiration technique, especially focusing on the degree of suction pressure and needle size.
MATERIALS AND METHODS
Three experienced radiologists performed ultrasound-guided aspiration for thyroid nodules in 1174 thyroid nodules consecutively. Three different techniques were used; (A) using a 25 gauge needle with mainly capillary technique in 269 nodules; (B) using a 25 gauge needle with 3 cc syringe and minimal suction pressure in 303 nodules; (C) using a 22-23 gauge needle with 10 cc syringe and aspirator in 602 nodules. The differences of the incidence of the insufficient cytology among the three aspiration techniques and relationships of the incidence and needle size/degree of suction pressure was statistically analyzed using the Mann-Whitney U test and the chi-square test with linear-by-linear association.
RESULTS
Overall, the difference in insufficient cytology was significant across the three aspiration technique (p = 0.004), and the incidence tended to increase significantly with increase of needle size and degree of suction pressure (p < 0.001). A pairwise comparison of aspiration techniques found significant differences (p = 0.003) between techniques (A) and (C), and no differences between technique (B) and (C) (p = 0.07) and between techniques (A) and (B) (p = 0.10).
CONCLUSION
The incidence of insufficient cytology was significantly low in the capillary technique, and it increased significantly with the increase of needle size and degree of suction pressure.


MeSH Terms

Biopsy, Fine-Needle
Capillaries
Incidence
Needles
Suction
Syringes
Thyroid Gland
Thyroid Nodule

Reference

1. Tublin ME, Martin JA, Rollin LJ, Pealer K, Kurs-Lasky M, Ohori NP. Ultrasound-guided fine-needle aspiration versus fine-needle capillary sampling biopsy of thyroid nodules: does technique matter? J Ultrasound Med. 2007; 26:1697–1701.
2. Haddadi-Nezhad S, Larijani B, Tavangar SM, Nouraei SM. Comparison of fine-needle-nonaspiration with fine-needle-aspiration technique in the cytologic studies of thyroid nodules. Endocr Pathol. 2003; 14:369–373.
3. Degirmenci B, Haktanir A, Albayrak R, Acar M, Sahin DA, Sahin O, et al. Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material. Clin Radiol. 2007; 62:798–803.
4. Romitelli F, Di Stasio E, Santoro C, Iozzino M, Orsini A, Cesareo R. A comparative study of fine needle aspiration and fine needle non-aspiration biopsy on suspected thyroid nodules. Endocr Pathol. 2009; 20:108–113.
5. Gümüş M, Cay N, Algin O, Ipek A, Ersoy RÜ, Belenli O, et al. Comparison of 21 and 27 gauge needles for determining sample adequacy in the aspiration biopsy of thyroid nodules. Diagn Interv Radiol. 2012; 18:102–105.
6. Tangpricha V, Chen BJ, Swan NC, Sweeney AT, de las Morenas A, Safer JD. Twenty-one-gauge needles provide more cellular samples than twenty-five-gauge needles in fine-needle aspiration biopsy of the thyroid but may not provide increased diagnostic accuracy. Thyroid. 2001; 11:973–976.
7. de Meer SG, Schreinemakers JM, Zelissen PM, Stapper G, Sie-Go DM, Rinkes IH, et al. Fine-needle aspiration of thyroid tumors: identifying factors associated with adequacy rate in a large academic center in the Netherlands. Diagn Cytopathol. 2012; 40:Suppl 1. E21–E26.
8. Hanbidge AE, Arenson AM, Shaw PA, Szalai JP, Hamilton PA, Leonhardt C. Needle size and sample adequacy in ultrasound-guided biopsy of thyroid nodules. Can Assoc Radiol J. 1995; 46:199–201.
9. İnci MF, Özkan F, Yüksel M, Şalk İ, Şahin M. The effects of sonographic and demographic features and needle size on obtaining adequate cytological material in sonography-guided fine-needle aspiration biopsy of thyroid nodules. Endocrine. 2013; 43:424–429.
10. Polyzos SA, Anastasilakis AD. A systematic review of cases reporting needle tract seeding following thyroid fine needle biopsy. World J Surg. 2010; 34:844–851.
11. Choi YS, Hong SW, Kwak JY, Moon HJ, Kim EK. Clinical and ultrasonographic findings affecting nondiagnostic results upon the second fine needle aspiration for thyroid nodules. Ann Surg Oncol. 2012; 19:2304–2309.
Full Text Links
  • JKSR
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr