J Korean Acad Oral Maxillofac Radiol.  1999 Feb;29(1):21-32.

Effect of variable scanning protocolson the pre-implant site evaluation of the mandiblein reformatted computed tomography

Affiliations
  • 1Department of Dental Radiology, College of Dentistry, Yonsei University, Korea.

Abstract

PURPOSE: To evaluate the effect of variable scanning protocols of computed tomography for evaluation of pre-implant site of the mandible through the comparison of the reformatted cross-sectional images of helical CT scans obtained with various imaging parameters versus those of conventional CT scans.
MATERIALS AND METHODS
A dry mandible was imaged using conventional nonoverlapped CT scans with 1 mm slice thickness and helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5, 2.0, 2.5 and 3.0. All helical images were reconstructed at reconstruction interval of 1 mm. DentaScan reformatted images were obtained to allow standardized visualization of cross-sectional images of the mandible. The reformatted images were reviewed and measured separately by 4 dental radiologists. The image qualities of continuity of cortical outline, trabecular bone structure and visibility of the mandibular canal were evaluated and the distance between anatomic structures were measured by 4 dental radiologists.
RESULTS
On image qualities of continuity of cortical outline, trabecular bone structure and visibility of the mandibular canal and in horizontal measurement, there was no statistically significant difference among conventional and helical scans with pitches of 1.0, 1.5 and 2.0. In vertical measurement, there was no statistically significant difference among the conventional and all imaging parameters of helical CT scans with pitches of 1.0, 1.5, 2.0, 2.5 and 3.0.
CONCLUSION
The images of helical CT scans with 1 mm slice thickness and pitches of 1.0, 1.5 and 2.0 are as good as those of conventional CT scans with 1 mm slice thickness for evaluation of pre-dental implant site of the mandible. Considering the radiation dose and patient comfort, helical CT scans with 1 mm slice thickness and pitch of 2.0 is recommended for evaluation of pre-implant site of the mandible.

Keyword

computed tomography; reformatted images; dental implant; mandible

MeSH Terms

Dental Implants
Humans
Mandible
Tomography, Spiral Computed
Tomography, X-Ray Computed
Dental Implants