J Korean Radiol Soc.  2002 Aug;47(2):233-239. 10.3348/jkrs.2002.47.2.233.

The Diagnostic Value of Contrast Enhanced Power Doppler US on Small Breast Lesions

Affiliations
  • 1Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Korea. kook3@samsung.co.kr
  • 2Department of Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Korea.

Abstract

PURPOSE
To evaluate the usefulness of contrast-enhanced power Doppler ultrasonography (PDUS) in differentiating small benign from small malignant breast lesions.
MATERIALS AND METHODS
Thirty-one solid breast lesions (<2 cm in size; 17 benign and 14 malignant) prospectively underwent US and PDUS before and after the injection of contrast agent (SH U 508A). Morphologic analysis involved independent assessment of the findings of US and the patterns of Doppler signals before and after contrast enhancement at PDUS, and sensitivity and specificity were thus evaluated. The diagnostic accuracy of US accompanied by PDUS was also determined before and after contrast enhancement. Hemodynamic analysis involved measurement of the time lapse between contrast injection at PDUS and observed change in Doppler signals. For this, a sonic VIOR computer-assisted program was used and the results were correlated with the pathologic findings.
RESULTS
The sensitivities of US before and after contrast enhanced PDUS were 100%, 35.7%, and 57%, with specificities of 47%, 88.2% and 76%, respectively. The diagnostic accuracy of US was 35% with noncontrast PDUS, and 77% before and after contrast enhanced PDUS. The recorded time lapse between contrast injection at PDUS and observed change in Doppler signals did not correlate closely with the pathologic findings.
CONCLUSION
In that it improved visualization of the morphology of vascular Doppler signals, microbubble contrast-enhanced PDUS complemented US and PDUS in differentiating between small benign and small malignant breast lesions.

Keyword

Breast neoplasms, diagnosis; Ultrasound (US), contrast media

MeSH Terms

Breast*
Complement System Proteins
Hemodynamics
Microbubbles
Prospective Studies
Sensitivity and Specificity
Ultrasonography, Doppler
Complement System Proteins
Full Text Links
  • JKRS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr