J Korean Hip Soc.  2007 Mar;19(1):9-15. 10.5371/jkhs.2007.19.1.9.

Cementless Total Hip Arthroplasty using Ceramic-on-ceramic Summit(R) System: 3 years follow up

Affiliations
  • 1Department of Orthopaedic Surgery, Yonsei University College of Medicine Yonsei University College Medicine, Seoul, Korea. ihyang@yumc.yonsei.ac.kr

Abstract

PURPOSE
To prospectively evaluate the 3 years follow up clinical and radiographic results of uncemented total hip arthroplasty using the Summit(R) system with ceramic-on-ceramic articulation.
MATERIALS AND METHODS
From January 2001 to December 2001, thirty-one primary total hip arthroplasties were performed on thirty-one patients using the Summit(R) system. The mean follow-up period was 3.3 years. The preoperative diagnoses were degenerative osteoarthritis in 18 cases, avascular necrosis in 10 cases, and a femoral neck fracture in 3 cases. The mean age at surgery was 67.4 years. The clinical results were evaluated using the Harris hip score. The radiographic evaluation was performed to determine the stability of the components, the prevalence of osteolysis and the amount of wear.
RESULTS
The mean Harris hip score improved from 64.7 points preoperatively to 90.4 points at the most recent follow-up. The complications included two cases of dislocation, three cases of limping gait lasting for 1 year after surgery. Fixation by bone ingrowth was noted in all cases and there was no case of migration of the acetabular cup and osteolysis. There was no case in the varus position, sinking down, or a loosening of the femoral stem. On the final observation after surgery, the range of hip joint motion showed flexion of 120.7degreeson average (110degrees~150degrees), extension of 5degrees(0degrees~10degrees), internal rotation of 20.3degrees(15degrees~25degrees), external rotation of 33.7degrees(20degrees~40degrees), abduction of 29.4degrees(20degrees~40degrees), and adduction of 19.5degrees(15degrees~25degrees).
CONCLUSION
Uncemented total hip arthroplasty using the Summit(R) system with ceramic-on-ceramic articulation showed excellent clinical and radiographic results in the range of motion and function.

Keyword

Summit(R) system; Total hip arthroplasty; Ceramic-on-ceramic articulation

MeSH Terms

Acetabulum
Arthroplasty
Arthroplasty, Replacement, Hip*
Diagnosis
Dislocations
Femoral Neck Fractures
Follow-Up Studies*
Gait
Hip
Hip Joint
Humans
Necrosis
Osteoarthritis
Osteolysis
Prevalence
Prospective Studies
Range of Motion, Articular

Cited by  3 articles

Comparative Analysis of Two Cementless Stems in Total Hip Arthroplasties in Patients with Osteonecrosis of Femoral Head - Summit® Stem and Bencox® Stem -
Young Wook Lim, Kee Haeng Lee, Sung Ho Bae, Soon Yong Kwon
J Korean Hip Soc. 2012;24(1):25-31.    doi: 10.5371/jkhs.2012.24.1.25.

Primary Total Hip Arthroplasty Using Summit® Stems in Korean: Minimum Four-year Follow-up
Jae Sik Yoon, Joon Sun Kang, Kyoung Ho Moon
Hip Pelvis. 2017;29(4):228-233.    doi: 10.5371/hp.2017.29.4.228.

Cementless Total Hip Arthroplasty Using Dual Offset Titanium Tapered Stem: At Least 7-Year Follow-Up
Kyung-Hoon Lee, Kee-Haeng Lee, Jongho Noh, Seong-Jun Kho
J Korean Orthop Assoc. 2017;52(5):419-427.    doi: 10.4055/jkoa.2017.52.5.419.

Full Text Links
  • JKHS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr