Prog Med Phys.  2014 Jun;25(2):95-99. 10.14316/pmp.2014.25.2.95.

Research of Efficiency for Gas Electron Multiplier Detector to Monitor Low Energy Gamma-Ray and Beta-Ray

Affiliations
  • 1Medical Research Institute, Ewha Womans University, Seoul, Korea.
  • 2Department of Radiation Oncology, School of Medicine, Ewha Womans University, Seoul, Korea. renalee@ewha.ac.kr

Abstract

Radiation monitoring is one of the most important process in all places where radioactive material is used including hospital. In this preliminary study, we made GAS electron multiplier (GEM) detector and acquired relative efficiencies in order to see if GEM detector can be useful in radiation monitoring system. The relative efficiency was acquired by using the ratio of GEM detector efficiency to CdTe detector efficiency. The relative efficiency of 72% and 4% was acquired for beta-ray and gamma-ray respectively.

Keyword

GEM detector; Efficiency

MeSH Terms

Radiation Monitoring

Figure

  • Fig. 1. (a) GEM detector, (b) GEM detector system.

  • Fig. 2. GEM 검출기 내부 구조.


Reference

References

1. 박인규: 방사선 검출기와 국제연구.물리학과 첨단 기술. 25–30. 2011.
2. Simon Frank: Commissioning of the G EM Detectors in the COMPAS Exp erime nt. Dip loma The sis. Physik Depa rtment, Technische Unive rsitat Munc hen (. 2011.
3. Buzulutskov A. Radiation dete ctors ba sed on gas e lec tron multipliers (R evi ew s). Instr um Exp Tech. 50(3):287–310. 2007.
4. 곽정원, 신정욱, 김진성 등. 전립선암에 대한 양성자치료에서 금마커에 의한 방사선 선량분포의 영향.의학물리. 21(3):291–297. 2010.
5. 전경수, 오영기, 백종근 등. 이온전리함 및 TLD법을 이용한 multi-detector comp uted tomogra phy의 흡수선량 및 체표면 선 량 평가.의학물리. 24(1):35–40. 2013.
6. Tsyganov Edward, Antich Peter, Parkey Robert, et al. Gas electron multiplying detectors for medical applications. Nucl Instru and Me th. 597(2):257–265. 2008.
Article
7. Fraga F, Margato L, Fetal S, et al. Luminescence a nd imaging with gas e lec tron multiplie rs. Nuc l Instru and Me th. 513(1):379–387. 2003.
8. Fabio Sauli: Development and applications of the gas electron multiplier. N uc l Instru and Me th. 513(1):115–119. 2001.
9. Peskov V, Fonte R, Danielsson M, et al. The study and optimization of new micropattern gaseous detectors for high rate applications. IEEE Tra ns Nuc l Sci 48 (4) (. 2001.
10. Yong HS, IG Kim, Hie HC, et al. Energy resolution of a single G EM dete ctor. Journal of the Kore an Physica l S ocie ty. 55(6):2366–2371. 2009.
11. Lepy Marie-Christine: Detection e fficie ncy, IAEA -ALMERA Technical Visit. (. 2010.
Full Text Links
  • PMP
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr