J Korean Cleft Palate-Craniofac Assoc.  2008 Oct;9(2):45-50.

The Result of Mandible Fracture Fixations with Biodegradable Materials

Affiliations
  • 1Department of Plastic and Reconstructive Surgery, Seoul National University College of Medicine, Seoul, Korea. sceun@snubh.org

Abstract

PURPOSE
Traditionally, titanium miniplate has been used for rigid fixation of mandible fractures. However, the limitations of metal plate have been reported such as hypersensitivity, interference with the cranio-facial growth of growing child, secondary bone resorption around the plate, foreign body reaction, declination of primary callus formation, and bone atrophy, and so forth. Recently, biodegradable miniplate has been introduced and used as an alternative to the metal plate despite of its lower strength. This study evaluated the usefulness and stability of biodegradable plate and screw for treatment of mandible fractures.
METHODS
In this study, 61 patients(92 areas) diagnosed as mandible fracture in the last 2 years have been reviewed. We used titanium plate and screw in 32 patients, and biodegradable plate and screw(INION?) in 29 patients. Stability of plates and screws, bony healing process and its side effects were observed by clinical and radiographic assessment.
RESULTS
In the titanium material group, one of malocclusion, two of mouth opening limitation, three of pain, three of palpation were shown. The plate of six patients involved in these complications were removed. In the biodegradable group, two of mouth opening limitation, two of pain, one of localized wound infection were shown and one plate was removed secondarily.
CONCLUSION
There was no statistical difference between two groups in bony healing and complication rates. Biodegradable implants show efficient stability during initial bone healing and low side effects in long-term follow up periods.

Keyword

Mandible fracture; Biodegradable plate

MeSH Terms

Absorbable Implants
Atrophy
Bone Resorption
Bony Callus
Child
Follow-Up Studies
Foreign-Body Reaction
Fracture Fixation
Humans
Hypersensitivity
Malocclusion
Mandible
Mouth
Palpation
Titanium
Wound Infection
Titanium
Full Text Links
  • JKCPCA
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles