J Korean Fract Soc.  2010 Jan;23(1):64-68. 10.12671/jkfs.2010.23.1.64.

Modified Spring Plate for Treatment of Unstable Distal Clavicle Fractures

Affiliations
  • 1Department of Orthopedic Surgery, St. Mary's Hospital, Seoul, Korea. skrhee@catholic.ac.kr
  • 2Department of Orthopedic Surgery, St. Mary's Hospital, The Catholic University of Korea College of Medicine, Bucheon, Korea.

Abstract

PURPOSE
Unstable distal clavicle fractures should be treated surgically but may be difficult in firm fixation because of small distal fragment. Although a variety of fixation methods have been currently used, none of the methods seem to be firm fixation and little pain. We present a new technique using a spring plate which was modified from one third tubular plate and report the early results.
MATERIALS AND METHODS
Modified spring plate was made from one third tubular plate and the distal hole of the plate was cutting and sharpened by rasp. The sharp edge was bent just like an animal claw (C shape). Between May 2007 and June 2009, a total of six patients with distal clavicle fracture were treated using modified spring plate. A sling was applied in the immediate post operative period for six weeks and exercises were started immediately.
RESULTS
Union was achieved in all cases with excellent results without complication (mean Constant score, 96). All patients had returned to ordinary daily activities but mild limitation of abduction (150 degrees ) by seven weeks after surgery. After six months, the plate was removed.
CONCLUSION
The modified spring plate has provided stable fixation for unstable distal clavicle fixation without disturbance to the acromioclavicular joint, subacromial space, or rotator cuff.

Keyword

Distal clavicle fracture; Modified spring plate; Acromioclavicular joint; Subacromial space; Rotator cuff

MeSH Terms

Acromioclavicular Joint
Animals
Clavicle
Exercise
Hoof and Claw
Humans
Rotator Cuff

Figure

  • Fig. 1 Close up photograph of modified spring plate. A newly designed spring plate which is made from ordinary one third tubular plate; The distal hole of the plate was cutting and sharpened by rasp. The sharp edge was bent just like an animal claw (C shape).

  • Fig. 2 (A) Distal clavicle comminuted fracture in a 47-year-old man. (B) After modified spring plate fixation. Note the acromioclavicular joint subluxation caused by acromioclavicular ligament damage. (C) After removal of modified spring plate.

  • Fig. 3 (A) Distal clavicle fracture in a 46-year-old man. (B) After modified spring plate fixation.


Reference

1. Allman FL Jr. Fractures and ligamentous injuries of the clavicle and its articulation. J Bone Joint Surg Am. 1967. 49:774–778.
Article
2. Constant CR, Murley AH. A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res. 1987. 214:160–164.
Article
3. Eiff MP, Hatch RL, Calmbach WL. Clavicle and scapula fractures. Fracture management for primary care. 1998. Philadelphia: Saunders Co;131–142.
4. Eskola A, Vainionpää S, Myllynen P, Pätiälä H, Rokkanen P. Outcome of clavicular fracture in 89 patients. Arch Orthop Trauma Surg. 1986. 105:337–338.
Article
5. Flinkkilä T, Ristiniemi J, Hyvönen P, Hämäläinen M. Surgical treatment of unstable fractures of the distal clavicle: a comparative study of kirschner wire and clavicular hook plate fixation. Acta Orthop Scand. 2002. 73:50–53.
Article
6. Henkel T, Oetiker R, Hackenbruch W. Treatment of fresh Tossy III acromioclavicular joint dislocation by ligament suture and temporary fixation with the clavicular hooked plate. Swiss Surg. 1997. 3:160–166.
7. Kang HJ, Park KK, Yoon HK, Song HK, Hahn SB. T plate fixation for unstable fracture of distal clavicle. J Korean Fract Soc. 2006. 19:329–334.
Article
8. Kona J, Bosse MJ, Staeheli JW, Rosseau RL. Type II distal clavicle fractures: a retrospective review of surgical treatment. J Orthop Trauma. 1990. 4:115–120.
9. Mast J, Jakob R, Ganz R. Planning and reduction technique in fracture surgery. 1989. New York: Springer-Verlag.
10. Meda PV, Machani B, Sinopidis C, Braithwaite I, Brownson P, Frostick SP. Clavicular hook plate for lateral end fractures:-a prospective study. Injury. 2006. 37:277–283.
Article
11. Neer CS 2nd. Fracture of the distal clavicle with detachment of the coracoclavicular ligaments in adults. J Trauma. 1963. 3:99–110.
Article
12. Neer CS 2nd. 5 Fractures of the distal third of the clavicle. . Clin Orthop Relat Res. 1968. 58:43–50.
Article
13. Park JY, Seo JB, Kim MH, Yu JW. Tension band fixation for type II fracture of the distal clavicle. J Korean Fract Soc. 2005. 18:421–425.
Article
14. Rockwood CA. Fractures of the outer clavicle in children and adults. J Bone Joint Surg Br. 1982. 64:642.
Full Text Links
  • JKFS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr