Korean J Audiol.  2011 Sep;15(2):62-66.

A Study on the Possibility of Occupational Noise-Induced Hearing Loss in Firefighters

Affiliations
  • 1Department of Preventive Medicine, Dongguk University College of Medicine, Occupational Safety and Health Research Institute, Gyeongju, Korea. kwaniya@dongguk.ac.kr
  • 2Department of Family Medicine, Dongguk University College of Medicine, Occupational Safety and Health Research Institute, Gyeongju, Korea.
  • 3Occupational Safety and Health Agency, Research Institute, Korea Occupational Safety and Health Agency, Incheon, Korea.

Abstract

BACKGROUND AND OBJECTIVES
Firefighters face serious risks to their health and safety in the performance of their duties. In addition to the diverse occupational hazards well-known to the public, firefighters are also occasionally exposed to high levels of noise, such as sirens, horns, and electronic alerting signals.
MATERIALS AND METHODS
We first measured the noise emitted by two fire trucks and one ambulance. Next, we enrolled 171 firefighters (164 males, seven females). We designated the employees of a private school as controls for the firefighter group. After selecting workers, including audiometric testing at 1,000 and 4,000 Hz, the groups were age- and gender-matched. Both groups were included separately for the right and left ears at pure-tone test frequencies at 1,000 and 4,000 Hz. We chose the better ear thresholds and analyzed the differences in hearing levels at each frequency and each age group between the firefighters and controls.
RESULTS
The sound pressure levels of the siren in and out of an ambulance, the first fire truck, and the second fire truck were 99.3 dB (A) and 108.9 dB (A), 92.3 dB (A) and 108.3, and 78.8 dB (A) and 99.0 dB (A), respectively. At 4,000 Hz, the hearing threshold was significantly increased by work period (p<0.01). Each hearing threshold level was significantly higher than controls (p<0.01).
CONCLUSIONS
Many of the noise sources produce sounds exceeding 90 dB (A), and some firefighters may be exposed for brief periods to levels that exceed 105-110 dB (A). The hearing threshold level in firefighters is higher than the general population and noise-induced hearing loss in firefighters is possible. In the future, consistent, effective, and long-standing implementation of hearing conservation programs are needed, and special health examinations for hearing levels in firefighters must be conducted.

Keyword

Firefighter; Hearing loss; Occupational noise

MeSH Terms

Ambulances
Animals
Ear
Electronics
Electrons
Enzyme Multiplied Immunoassay Technique
Firefighters
Fires
Hearing
Hearing Loss
Hearing Loss, Noise-Induced
Horns
Humans
Male
Motor Vehicles
Noise
Noise, Occupational
Full Text Links
  • KJA
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr