Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

21 results
Display

The Availability of Contrast Sensitivity in Low Vision Patients

Park SL, Moon NJ

  • KMID: 2108524
  • J Korean Ophthalmol Soc.
  • 1998 Aug;39(8):1788-1793.
The standard vision test using visual acuity is not always an accurate indicator of functional visual loss. The contrast sensitivity was measured in low vision patients. the contrast sensitivity of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Simplified Vision Test Chart for Screening Test

Hahn CS

  • KMID: 2042557
  • J Korean Ophthalmol Soc.
  • 1986 Dec;27(6):991-994.
1. A simplified vision test chart which is composed of test types of arabic figures and Landolt's rings for 0.1, 0.3, 0.5, 0.8 and 1.0 was designed by the author....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Korean Near Vision Chart

Hahn CS

  • KMID: 1948642
  • J Korean Ophthalmol Soc.
  • 1964 Nov;5(2):7-10.
New Korean near vision chart was designed by the author and presented. As for the test types, photographically reduced optotypes of the Korean Test Chart for distance, published in Sep....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Computerized Scoring Method of The Hahn Double 15 Hue Test

Park WS, Lee JY

  • KMID: 2282820
  • Korean J Prev Med.
  • 1996 Sep;29(3):521-528.
The Hahn double 15 hue test is used for social and vacational aptitude test to separate strongly and mildly affected subjects among the colour vision defective persons, detected using colour...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Aasesament of Contrast Sensitivity by MCT 8000(R) in Normal Eyes and Peeudophakic Eyes

Kim YS, Yoo CS, Kim JH

  • KMID: 2107576
  • J Korean Ophthalmol Soc.
  • 1989 Oct;30(5):701-708.
The standard vision test using Snellen acuity is not always an accurate indicat or of functional vision loss. Acuity measures optical blur, but psudophakic eyes frequently do not affect optical...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Binocular Single Vision in Korean

Kim CH, Ahn JH, Jang JW

  • KMID: 2206305
  • J Korean Ophthalmol Soc.
  • 2002 Dec;43(12):2500-2505.
PURPOSE: The binocular single vision test plays an important role in evaluating severity and progression of diplopia, and a motility disorder. The purpose of this study is to determine the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Examination of Cheongsan Vision Chart

Hahn CS

  • KMID: 2336429
  • J Korean Ophthalmol Soc.
  • 1987 Jun;28(3):599-604.
The accuracy of vision test chart is very important in examination of the visual acuity. The author examined the accuracy of the Cheongsan Vision Chart which is an imitative print...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A New Design of Vision Test Chart

Chai BS

  • KMID: 2336340
  • J Korean Ophthalmol Soc.
  • 1974 Dec;15(4):279-281.
A new model of test chart for accurate and simpler measurement of visual acuity is introduced. The test chart is composed of Landolt's rings, Arabic figures, and Korean letters following...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Repeatability and Validity of the VAA-2000 Automated Self Vision Tester

Kee HJ, Yang HK

PURPOSE: To evaluate the test-retest reliability and validity of the VAA-2000 Self Vision Tester. METHODS: A total of 108 eyes of 108 adults (55 men and 53 women) who visited Seoul...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Study on the Clinical Usefullness of Digitalized Random-dot Stereoacuity Test

Yang JW, Son MH, Yun IH

Existing methods of stereoacuity testing need specific glasses or optical device for use. We have designed a new stereoacuity test for the digitalized, random-dot stereogram and researched its clinical usefulness....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Case of Ahmed Glaucoma Valve Implantation without Removal of the Anterior Chamber Lens

Lee E, Park SJ, Kwon JD

PURPOSE: To report the results of performing an Ahmed glaucoma valve implantation without removing the anterior chamber lens to treat secondary glaucoma. CASE SUMMARY: A 72-year-old male visited the hospital for...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Shift of Colorimetric Values in Ishihara Pseudoisochromatic Plates with Plate Aging

Hyon JY, Lee JH, Wee WR

PURPOSE: This study aimed to quantify the shift of colorimetric values in the Ishihara pseudoisochromatic test with aging of the plates. METHODS: Three sets of Ishihara pseudoisochromatic plates with different...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Measurement of Strabismic Angle Using the Distance Krimsky Test

Joo KS, Koo H, Moon NJ

PURPOSE: To evaluate the correlation of the distance Krimsky test and the alternate prism cover test (APCT) for the distance deviation in patients with horizontal strabismus. METHODS: Forty patients with horizontal...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Transient Increase of Higher-Order Aberrations after Lateral Rectus Recession in Children

Seo KY, Hong S, Song WK, Chung SA, Lee JB

The changes of higher-order aberrations (HOAs) after bilateral lateral rectus muscle recession were evaluated. Forty eyes of 20 children were enrolled and their wavefront information was assessed until postoperative 3...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Novel Computerized Visual Acuity Test for Children

Shin YJ, Lee IB, Wee WR, Lee JH, Hwang JM

PURPOSE: To investigate the efficacy of a computerized visual acuity test, the SNU visual acuity test for children. METHODS: Fifty-six children, ranging from 1 to 5 years of age, were included....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Visual Quality after Wavefront-Guided LASIK for Myopia

Kim H, Joo CK

This study evaluated the visual quality after wavefront-guided laser in situ keratomileusis (LASIK) for treating myopia. Thirty-two eyes with moderate myopia (-5.78~-2.17D) and 25 eyes with high myopia (-7.78~-6.17D) were...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Higher-Order Aberration and Contrast Sensitivity in Monofocal and Multifocal Intraocular Lenses

Kim CY, Chung SH, Kim TI, Cho YJ, Yoon G, Seo KY

PURPOSE: The visual performance of pseudophakic eyes depends on the type of intraocular lenses (IOLs) that are implanted. Aspherical and multifocal IOLs have recently been developed to improve visual quality...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Argon Laser Iridotomy

Lee SH

  • KMID: 2336443
  • J Korean Ophthalmol Soc.
  • 1987 Jun;28(3):599-605.
Argon laser iridotomy was performed on 67 eyes, 49 patients with angle-closure glaucoma: 24 eyes(18 patients) with acute angle-closure glaucoma, 15 eyes(12 patients) with chronic angle-closure glaucoma, 4 eyes(4 patients)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Correlations between Preoperative Angle Parameters and Postoperative Unpredicted Refractive Errors after Cataract Surgery in Open Angle Glaucoma (AOD 500)

Lee W, Bae HW, Lee SH, Kim CY, Seong GJ

PURPOSE: To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Intraocular Lens Power Estimation in Combined Phacoemulsification and Pars Plana Vitrectomy in Eyes with Epiretinal Membranes: A Case-Control Study

Kim M, Kim HE, Lee DH, Koh HJ, Lee SC, Kim SS

PURPOSE: To evaluate the accuracy of postoperative refractive outcomes of combined phacovitrectomy for epiretinal membrane (ERM) in comparison to cataract surgery alone. MATERIALS AND METHODS: Thirty-nine eyes that underwent combined phacovitrectomy...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr